4.2.3 Universal Pulse Transmitter
The AccuLoad uses the I/O connection points in the following table to connect to the Smith Meter Universal
Pulse Transmitter (UPT).
4.2.4 PPS Transmitter
The AccuLoad uses the I/O connection points in the following table to connect to the Smith Meter
Photoelectric Pulse Security (PPS) Transmitter.
Table 25: UPT Connections
AccuLoad Connections
UPT Connections
Pulse input A plus
Terminal 5 (signal A output)
Pulse input B plus (dual-pulse only) Terminal 3 (signal B output); not used for single-channel
connection
Pulse input A and B minus connect
to DC ground
+ 24 VDC
Terminal 2 (input power)
DC ground
Terminal 1 (electronics ground)
Pulse input A integrityplus
Terminals 6 (signal A integrity output); not used for non-
integrity connection
Pulse input B integrity plus
Terminals 4 (signal A integrity output); not used for non-
integrity connection
Terminal 7 (shield); no connection
Terminal 8 (verification pulse output); connect to optional
verification device
Terminal 9 (inverted verification pulse output); connect to
optional verification device
Terminal 10; no connection
Table 26: PPS Transmitter Connections
AccuLoad Connections
PPS Transmitter Connections
Pulse input A plus
Terminal 5 (signal A output)
Pulse input B plus (dual-pulse only) Terminal 3 (signal B output); not used for single-channel
connection
Pulse input A and B minus connect
to DC Ground
+ 24 VDC
Terminal 2 (input power)
DC ground
Terminal 1 (common)
Pulse input A integrity plus
Terminals 6 (signal A integrity output); not used for non-
integrity connection
Pulse input B integrity plus
Terminals 4 (signal A integrity output); not used for non-
integrity connection
Содержание Smith Meter AccuLoad IV
Страница 7: ...AccuLoad IV Installation Maintenance Manual Introduction 2 Figure 1 AccuLoad IV ST ...
Страница 9: ...AccuLoad IV Installation Maintenance Manual Introduction 4 Figure 3 AccuLoad IV QT ...
Страница 11: ...AccuLoad IV Installation Maintenance Manual Introduction 6 Figure 5 AccuLoad IV N4 ...
Страница 14: ...AccuLoad IV Installation Maintenance Manual Introduction 9 Figure 8 AccuLoad IV SA FCM ...