AccuLoad IV Installation & Maintenance Manual
Meter I/O Connections
51
The tables in the following sections detail the pulse input assignments made by the AccuLoad for each of
the possible number of product meters. Any pulse inputs not required for connection of the product meters
are available to be configured for use as an additive meter or pulse densitometer.
The following conventions are used in the tables below:
•
Bold, italicized
text is used to indicate a different between AccuLoad III and AccuLoad IV
connections.
•
The product meter naming convention used is:
•
M = meter
•
Number = meter number
•
Letter = channel
For example, M2A.
•
“Pgm” means that the pulse output is programmable so it can function as a metered injector or a
densitometer pulse input.
•
“n/a” means that the pulse input is not applicable.
4.3.1 Meter Inputs for ST and N4 Models
Refer to the following tables regarding meter inputs for the ST and N4 models.
In the AccuLoad IV, the valve control solenoid outputs or metered injector solenoid outputs must be
configured or landed on the same board as the associated meter pulse input.
Table 31: Six-Product Meters (AccuLoad IV Models ST and N4)
In #1 In #2 In #3 In #4 In #5 In #6 In #7 In #8
Single pulse
M1A
M2A
M3A
M4A
M5A
M6A
Pgm
Pgm
Dual pulse
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Dual pulse with integrity
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Table 32: Five-Product Meters (AccuLoad Models ST and N4)
In #1 In #2 In #3 In #4 In #5 In #6 In #7 In #8
Single Pulse
M1A
M2A
M3A
M4A
M5A
Pgm
Pgm
Pgm
Dual Pulse
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Dual pulse with integrity
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Table 33: Four-Product Meters (AccuLoad Models ST and N4)
In #1 In #2 In #3 In #4 In #5 In #6 In #7 In #8
Single Pulse
M1A
M2A
M3A
M4A
Pgm
Pgm
Pgm
Pgm
Dual Pulse
M1A
M1B
M2A
M2B
M3A
M3B
M4A
M4B
Dual pulse with integrity
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Содержание Smith Meter AccuLoad IV
Страница 7: ...AccuLoad IV Installation Maintenance Manual Introduction 2 Figure 1 AccuLoad IV ST ...
Страница 9: ...AccuLoad IV Installation Maintenance Manual Introduction 4 Figure 3 AccuLoad IV QT ...
Страница 11: ...AccuLoad IV Installation Maintenance Manual Introduction 6 Figure 5 AccuLoad IV N4 ...
Страница 14: ...AccuLoad IV Installation Maintenance Manual Introduction 9 Figure 8 AccuLoad IV SA FCM ...