![TechnipFMC Smith Meter AccuLoad IV Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/technipfmc/smith-meter-accuload-iv/smith-meter-accuload-iv_installation-and-maintenance-manual_1069431036.webp)
AccuLoad IV Installation & Maintenance Manual
Installation
31
The following drawing shows the A4I board’s I/O connections.
The A4I board has jumpers that allow customization. If the A4I board is connected to additive meters for
which the transmitters require DC power, the voltage select jumpers (see
)
are used to set the meter power supply voltage to 5, 12, or 24 VDC.
Firmware updates are not available over serial connections in the A4I.
Table 14: A4I Jumper Settings
Designation
Jumpers
Description
5V
1 and 2
24 V – +V Out
12V
3 and 4
12 V – +V Out
24V
5 and 6
5 V – +V Out
Figure 19: A4I Connections
Enet
2
Enet
1
S1
OFF
1
8
ON
TB9
Out 1-Out 10
TB8
N/C 12
N/C
11
Out 1
10
Out 2
9
Out 3
8
Out 4
7
Out 5
6
Out 6
5
Out 7
4
Out 8
3
Out 9
2
Out 10
1
CN5
5
3 1
•
•
•
•
•
•
6
4 2
F1
TB5
1
+V Out
2
Inj Pulse/DC In 1
3
Common
4
+V Out
5
Inj Pulse/DC In 2
6
Common
7
+V Out
8
Inj Pulse/DC In 3
TB4
1
Common
2
+V Out
3
Inj Pulse/DC In 4
4
Common
5
+V Out
6
Inj Pulse/DC In 5
7
Common
8
+V Out
9
Inj Pulse/DC In 6
10
Common
TB3
1
+V Out
2
Inj Pulse/DC In 7
3
Common
4
+V Out
5
Inj Pulse/DC In 8
6
Common
7
+V Out
8
Inj Pulse/DC In 9
9
Common
10
+V Out
11
Inj Pulse/DC In 10
12
Common
TB2
1
RS485 (Rx -)
2
RS485 (Rx +)/RS232 (Rx)
3
RS485 (Tx -)
4
RS485 (Tx +)/RS232 (Tx)
TB1
1
+24 VDC
DC Input
2
Gnd/RS232 Com
TB7
Out 11
10
Out 12
9
Out 13
8
Out 14
7
Out 15
6
Out 16
5
Out 17
4
Out 18
3
Out 19
2
Out 20
1
TB6
Out 11-Out 20
Earth Ground
to Circuit Ground
InV Out Selection
1-2
24V
3-4
12V
5-6
5V
J1
•
•
A4I
Содержание Smith Meter AccuLoad IV
Страница 7: ...AccuLoad IV Installation Maintenance Manual Introduction 2 Figure 1 AccuLoad IV ST ...
Страница 9: ...AccuLoad IV Installation Maintenance Manual Introduction 4 Figure 3 AccuLoad IV QT ...
Страница 11: ...AccuLoad IV Installation Maintenance Manual Introduction 6 Figure 5 AccuLoad IV N4 ...
Страница 14: ...AccuLoad IV Installation Maintenance Manual Introduction 9 Figure 8 AccuLoad IV SA FCM ...