Now you are prepared to run the update:
1.
Make sure your network-adapter is configured with correct IP address
2.
Apply “F” to the
rotary switch
3.
Power up the device. If you Power up the in rotary switch positio
n “F”, the device
gets always the default IP 192.168.0.49!
4.
Connect a Windows PC with a RJ45 cable directly to MediaConverter or
MediaGateway and make sure there is a link by checking the LEDs blinking. Do
not connect a switch in between.
5.
Start “
Flash ALL_192.168.0.49.bat
” from the same folder as the firmware files are
stored.
6.
Wait until “Press any key . . .“ appears in cmd
-window.
7.
Press any key
8.
Do a power reset
9.
Check the Host-LED if blinking in normal mode.
10.
YES => check webserver by browser
NO => redo from point 5.