CM CAN Combo
User Manual
16
2.1.5
Micro HDMI connector
This is an interface for programming and debugging (only for development.)
2.2
Other Interfaces
2.2.1
Rotary switch
The following IPs will be set as default for the CM_CAN_Combo.
You get access to the Webserver only by the configured configuration port. Out of the
box the 1000BASE-T-Port is set as the configuration port.
•
Rotary switch on 0 -> IP: 10.104.3.64
•
Rotary switch on 1 -> IP: 10.104.3.65
•
...
•
Rotary switch on D -> IP: 10.104.3.77
•
Rotary switch on E -> IP: 10.104.3.78
•
Rotary switch on F -> IP: 10.104.3.79 / Reset
2.2.1.1
Rotary switch in status 0 to D
The IP addresses are not configurable by software or by any user interface and can
only be changed by using the rotary switch. It is overtaken after 500ms by a software
reset. The current IP address is shown on the System Information tab. Access to the
CM_CAN_Combo is given through the defined configuration port: 1000BASE-T-port or
100BASE-T1 Ports on the Frontside (Host).
The set IP address is part of the TECMP header if TECMP is activated.
2.2.1.2
Rotary switch in status E
The IP address 10.104.3.78 is the default IP address. In this Rotary switch status the
IP address is configurable on the System Information tab. The configured IP address
is valid even there is a power reset, or the Rotary switch has been changed and is
switched back to “E”. The valid
IP address in this Rotary switch position is part of the
TECMP header if TECMP is activated.
2.2.1.3
Rotary switch in status F
The IP address 10.104.3.79 is the default IP address. It is not configurable. The IP
address is not overtaken after changing the rotary switch from any position to position
“F”. There
will be no software reset. A power reset is needed. But if there is a power
reset in this Rotary switch status, the CM_CAN_Combo will be reset to out of the box
status.
Complete
configuration will be lost and set to default.