CM CAN Combo
User Manual
48
Keep Awake Reason Bus
:
This port is supervised. If on this port is communication, CM_CAN_Combo
can’t
go asleep.
This port is not supervised. The Capture Module can fall asleep even there is
communication on this port.
Channel ID
: It is a hexadecimal nu
mber. E.G “B0”
. It is a number assigned to any port
separately. For further information see definition of TECMP-protocol.
Time Stamp
:
Timestamp is in nano seconds [ns] resolution and with an accuracy of 40 nano
seconds [ns] (starting with epoch time, if no PTP master is connected)
Messages Received
: Counter for received messages on this port from the connected
RS232-port
Messages with Error
: Counter for received messages on this port from the connected
RS232-port containing an error. For example CRC errors.
Serial Output Level
:
RS232
TTL (Transistor-Transistor-Logic)
4.6
XCP Tab
Figure 4-26: XCP tab
This is the Homescreen of XCP-Configuration. XCP is the Extended CAN Protocol.
By this option you can request further information from your DUT over CAN-Bus, if this
is available for the specific DUT. For automatic configuration you need a specific A2L-
file for your DUT and a specific XCP-Tool. Please contact
for the tool and further information provided with the tool.
If there is anything already configured, after every software or hardware reset of the
CM_CAN_Combo will start with XCP.
Init
: By clicking on this-Button, you can add new XCP requests. The following screen
with two tables appears: