UNIT
NARROW TUBE
LARGE TUBE
MODEL
OUTSIDE DIA.
OUTSIDE DIA.
6,35 mm
7,93 mm
6,35 mm
9,52 mm
Separately insulated
HEATING
OUTDOOR TEMPERATURE 24°C D.B./18°C W.B.
ROOM TEMPERATURE
27°C D.B.
OUTDOOR TEMPERATURE -8°C D.B./-9°C W.B.
●
Anti-freeze oil for Aeroquip connections (for models with R407C use synthetic oil HAB - Alkylbenzene type ex. ZERICE S
EXXON), about 30 gr.
●
PVC pipe to insulate hole in the wall, external diameter 50 mm. of minimum length as for thickness wall.
2
COOLING
OUTDOOR TEMPERATURE 46°C D.B.
ROOM TEMPERATURE
32°C D.B./23°C W.B.
OUTDOOR TEMPERATURE 19°C D.B.
ROOM TEMPERATURE
19°C D.B./14°C W.B.
POWER SUPPLY 220 / 240V ~ 50 Hz
(TO BE CONTINUED AT PAGE 3)
MAXIMUM CONDITIONS
OPERATING LIMITS
MINIMUM CONDITIONS
THE EXTENSION KITS ARE SUPPLIED PRECHARGED
Before the installation, verify that they are fit for the unit.
MAXIMUM CONDITIONS
MINIMUM CONDITIONS
GENERAL PRECAUTION
●
Check that the voltage and frequency of the power supply match those required
by the system.
●
Check the possibility to have the power line to the indoor unit (ELECTRIC
CABLE LENGTH 3 m).
●
Install a double - pole switch, protected by 10 A fuses of the delayed type,
upstream the electricity wall socket.
●
Verify that the power supply available is sufficient for running other electri-
cal domestic appliances in use simultaneously from the same supply.
●
Before connecting the air conditioner to a power socket, make sure
that the socket is provided with an earth connection in compliance
with local codes.
●
Phillips head screw driver
●
Tape measure
●
Level
●
Hammer drill
●
Hole saw or key hole saw ø 50
●
19 mm wrench
●
21
mm wrench
●
24 mm wrench
●
Hammer
●
Hacksaw
●
Core bits 10 mm diameter drill bit.
INSTALLATION SITE SELECTION
TOOLS REQUIRED FOR INSTALLATION
(NOT SUPPLIED)
ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION
(NOT SUPPLIED)
INDOOR UNIT
AVOID:
●
Positioning the indoor unit into rooms where it could be sprinkled
with water (i.e. laundries).
●
To install in areas where leakage of
flammable gas or large amount of mist may be expected humidity
location.
●
Direct sunlight or near by heat source that may affect per-
formance of the unit.
●
Installing unit behind curtains or furniture that
obstruct air circulation.
DO:
●
Choose a position which allows proper ventilation in the room.
●
Verify respect of the minimum recommended maintenance space.
OUTDOOR UNIT
AVOID:
●
Direct sunlight or area where hot air from exhaust fans investing the unit.
DO:
●
Choose a place as cool as possible and well ventilated.
ACCESSORIES SUPPLIED WITH THE UNIT
PARTS
FIGURE NR°
REMOTE CONTROL
UNIT
RAWL PLUG S X 5
SCREW 4,2x32
WASHER
PLASTIC PLUG
(
MALE AND FEMALE
)
RAWL PLUG S X 10
SCREW 7x65
WASHER
OUTDOOR UNIT
BASKET OR
SUPPORT
1
2
2
2
2 + 2
2/3
2/3
2/3
1
CONNECTION EXTENSION
KITS - LENGHT OF 2 OR 4 m
ACCESSORY SUPPLIED ON REQUEST
*
For heat pump version.
PARTI
FIGURA N°
EXTENSION KIT
FOR CONNECTION
TUBE
CONNECTIONS
PLASTIC BOX
RAWL PLUG
TAPPING SCREW
ø 3,5 x 45
CLAMP
1
1
3
3
2 + 8
*
EG
DECLARATION OF CONFORMITY
This product is marked as it satisfies Directives.
- Low voltage no. 73/23/CEE and 93/68/CEE.
- Electromagnetic compatibily no. 89/336/CEE,
92/31/CEE and 93/68/CEE.
This declaration will become void in case of misusage
and/or non observance though partial of Manufacturer’s
installation and/or operating instructions.
COOL/DRY/FAN
COOL/DRY/HEAT/FAN