background image

 

3

SAFETY 

 

1.1 Intended Use: 
 
WARNING: Use of this equipment in ways other than those 
described in this User Guide may result in injury to persons or 
damage to property. Use this equipment only as described in 
this User Guide. 
 

OK International cannot be responsible for injuries or damages 
resulting from unintended applications of its equipment.  Unintended 
uses may result form taking the following actions: 

  Making changes to equipment that has not been recommended 

in the User Guide 

  Using incompatible or damaged replacement parts. Using 

unapproved accessories or auxiliary equipment 
 

1.2 Safety Precautions: 

  Do not operate this unit in excess of maximum ratings/settings 

  Always wear appropriate personal protective clothing or apparel 

  Care must be taken to prevent the ingress of corrosive or 

flammable fluid back into the Refer to Material Safety Data Sheet 
for proper handling and safety precautions 

  Do not smoke or use open flame when flammable materials are 

being dispensed 

  This equipment is for indoor use only.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

4

2 DESCRIPTION 

 

The TS6500CIM Series Automatic Techkit Mixer provides complete 
automatic mixing of two-component material package in cartridge 
kits.  Equipped with a universal power supply, the TS6500 mixer is 
immediately usable anywhere in the world.   The automatic fluid 
sensing device makes it very simple for operator to install and setup 
all cartridge kit sizes.  The user friendly firmware provides up to 10 
programmable mixing sequences with storage of 10 profiles. 
 
The TS6500CIM Series is available in two versions: 

 

TS6500CIM-6 for 2.5 (74ml), 6.0 (177ml) and 8.0 oz. (237ml) Kit 

 

TS6500CIM-20 for 20 oz.(591ml) Kit 

 

The following conversion kits are also available for your 
conveniences: 

 

CK6500-6 Conversion kit for 2.5 (74ml), 6.0 (177ml) and 8.0 oz. 
(237ml) Kit 

 CK6500-10 

Conversion 

kit 

for 1/10 gal.(325ml) Kit 

 

CK6500-20 Conversion kit for 20 oz.(591ml) Kit 

 

 

3 SYMBOL 

DEFINITIONS 

 

Symbol Definition 

 

Power 
On/Off 

 

Cycle 
Mode 

Setup 

 
 
 
 
 
 
 
 
 
 

Содержание TS6500

Страница 1: ...on the Unit 12 6 3 Cartridge Kit Preparation 13 6 4 Loading the Cartridge Kit 14 6 5 Spindle Extension Installation 15 6 6 Mix Cycle Program Setup 16 6 7 Start the Unit 16 6 8 Unloading the Cartridge...

Страница 2: ...roper handling and safety precautions Do not smoke or use open flame when flammable materials are being dispensed This equipment is for indoor use only 4 2 DESCRIPTION The TS6500CIM Series Automatic T...

Страница 3: ...0 relative humility at 104 F 40 C Air Input 50 to 100psi 3 5 6 9 Bar Display LCD 20 X 4 display segments 4 1 Outside Dimensions 398mm 15 7 319mm 12 6 380mm 15 0 537mm 21 2 120mm 4 7 1032mm 40 6 Figure...

Страница 4: ...4 Cartridge Holder Bracket Figure 4 0 Partial Side View Figure 3 Back View 24 23 22 21 17 18 19 20 8 Figure 5 0 Buttons and Screen Identification MIX CYCLE SET PROGRAM MODE PRESSURE TOTAL MIX TIME SAF...

Страница 5: ...lays unit status operation and error messages 12 Protective Safety Cover Protect operators when machine in use 13 Plunger Disk Part or Plunger Assembly 14 Fluid Level Sensor Senses the fluid level at...

Страница 6: ...rn On the Unit 1 Insert the power cord to the power socket Fig 3 20 Caution Make sure the proper fuse has been installed and correct voltage has been set Refer to section 6 1 for instructions 2 Connec...

Страница 7: ...etup to mix cartridge kit with 8 203mm mix rod To mix cartridge kit with 6 152mm mix rod the spindle extension needs to be installed Refer to section 6 5 for instructions b The TS6500CIM 6 is setup to...

Страница 8: ...and button to adjust delay time 6 Press and hold the Setup button for 3 seconds to save data The unit is now ready to run 6 7 Start the unit 1 Ensure the unit is in the Automatic Mode and the desired...

Страница 9: ...not fully closed Check power cord connections Turn Emergency button clockwise to release Closed safety door LCD does not light No power input Check power cord connections Check Fuse Turn on power Air...

Страница 10: ...6 0 oz 177ml kit To mix the 2 5 74ml or 8 0 oz 237ml kit the cartridge holder needs to be re install at different mounting locations as shown in Fig 10 Mounting Location for 2 5 oz 74ml Kit Mounting...

Страница 11: ...h defective product under warranty must contact the nearest OK International office or distributor to secure a return authorization prior to shipping the product to the assigned OK International autho...

Страница 12: ...0 0060 VOLTAGE SELECT SWITCH 1 44 2100 0372 POWER CONNECTOR 1 Figure 19 0 Inside Front Cover Assembly 24 Figure 19 0 Inside Assembly Level 2 ITEM PART NUMBER DESCRIPTION QTY 45 TSD650 21 SOLENOID VALV...

Страница 13: ...m Injection 600 80 8 203mm Injection 8 0 oz 237ml 800 61T 6 152mm Taped Barrier 800 81T 8 203mm Taped Barrier 800 60 6 152mm Injection 800 80 8 203mm Injection 20 oz 591ml 200 81T 8 203mm Taped Barrie...

Отзывы: