ST – 480

III.a.5) Single step

You can use this function to set a percentage value for a single step in the

operation of valve opening, that is to say the maximum percentage value of
opening   or   closing   that   the   valve   can   move   in   a   single   step   (maximum
movement of the valve in one measurement cycle). 

III.a.6) Minimum opening

Use this function to set the minimum value for valve opening. Below this

value, the valve will not close shut.

III.a.7) Type of valve

You can use this option to select the type of valve: central heating

or floor type. 

III.a.8) Weather program (weekly valve program)

In   order   to   enable   the   weather   function   an   outdoor   sensor   should   be

installed in a place not exposed directly to sunlight or weather conditions. 
 After installing and connecting the sensor the Weather program function must
be enabled in the controller menu. 

For the valve to work properly enter set-point temperatures (downstream

of the valve) for the following four intermediate outside temperatures: 

   TEMP. FOR

 -20

   TEMP. FOR 

-10

                 

TEMP. FOR 

0

                 

TEMP. FOR 

10

Heating curve - curve which is used to determine the set-point temperature of

- 15 -

Содержание ST-480

Страница 1: ......

Страница 2: ...Wieprz is compliant with the Regulation by the Ministry of Economy Journal of Laws Dz U 155 Item 1089 of July 21 2007 implementing provisions of the Low Voltage Directive LVD 2006 95 EC of January 16...

Страница 3: ...d from the mains before working on the power supply cable connections device installation etc All connection works must only be carried out by qualified electricians Before activating the controller m...

Страница 4: ......

Страница 5: ...ration parameters are shown Exemplary view of the main screen Any remarks regarding the programme should be reported to the boiler manufacturer Each driver should be adjusted according to individual n...

Страница 6: ...be selected by pressing the knob Similar procedure is followed when changing the parameters In order for the changes to be input they need to be confirmed by pressing the pulser after the CONFIRM mes...

Страница 7: ...system temperature can be adjusted using the room temperature reduction function see Item II 15 and the weekly control function see Item II 6 The preset temperature is a sum of all those values but it...

Страница 8: ...rent time and date first Installer menu Clock Step 2 The user sets temperature values for individual days of the week Set mode 1 Monday Sunday Select specific hours and required deviations from the pr...

Страница 9: ...perature change 5 C In this case if the preset boiler temperature is 60 C the temperature will drop 10 C to 50 C between 3 a m and 6 a m on each day from Monday to Friday However the temperature will...

Страница 10: ...pump is turned on and off independently and sound is produced A message reading Central heating system temperature is not rising appears on the display The alarm is cancelled by pressing the pulser k...

Страница 11: ...iler instantaneous set point so as to prevent overheating of the boiler NOTE The boiler must be fitted with check valves on the central heating and hot water pump circuits The valve mounted on the hot...

Страница 12: ...e sustain mode Inappropriate selection of working and pause times may result in further temperature rise or unintended boiler shutdown or even lead to conditions where the fuel in the fuel tank gets f...

Страница 13: ...settings saved in user s menu being lost and reset to boiler manufacturer s settings Individual boiler parameters can be set at that point again ATTENTION Restoration of factory settings will not cau...

Страница 14: ...nd separately for each of the valves III a 3 Temperature control This parameter determines the sampling control frequency of the water temperature downstream of the valve for the central heating or ho...

Страница 15: ...ou can use this option to select the type of valve central heating or floor type III a 8 Weather program weekly valve program In order to enable the weather function an outdoor sensor should be instal...

Страница 16: ...weather control is enabled the valve set point parameter is calculated based on the heating curve By changing this parameter you can decrease or increase all the weather control settings III a 9 Retu...

Страница 17: ...t reduction value see Section II a 10 dynamic changes when you select this mode after heating up the house flat to the set point temperature the TECH room thermostat will work as per the following set...

Страница 18: ...nly possible after you purchase and connect the controller to an additional control module ST 61 which is not provided as standard equipment with the controller In order to control two valves you need...

Страница 19: ...its type module controller traditional two state type from the module standard or TECH controller traditional two state type from the controller TECH algorithm controller RS communication room temper...

Страница 20: ...r as per the controller sensors Main controller III b 13 Room thermostat reduction Setting as for the main valve see Section III a 10 III b 14 External sensor adjustment The external sensor is to be a...

Страница 21: ...ture is higher than the preset one the pumps are working but they operate depending on the operation mode see pump operation modes III 2 Boiler hysteresis This option is used to set the hysteresis of...

Страница 22: ...the operation involves the mixing valve the user may preview the current external temperature while viewing the main screen with the valve parameters After TECH Controller option is enabled a letter...

Страница 23: ...rk On the home computer screen the user controls the condition of all boiler system devices and the operation of each device is presented in the animated form Apart from the possibility to view the te...

Страница 24: ...C below the pre set value III 10 Circulation pump The function allows to control the pump which is used to mix hot water between the boiler and the domestic hot water taps After the function is activa...

Страница 25: ...s to select the controller type connected to ST 480 controller to operate with the above selected unit Two options are available two state standard controller TECH controller After TECH Controller opt...

Страница 26: ...disconnecting the fan and the feeder in the event of exceeding the alarm temperature 85O C Its activation prevents the water in the installation from boiling in the event when the boiler overheats or...

Страница 27: ...o high Despite damage of the bimetallic sensor the controller receives information on the current temperature in the boiler from the electronic sensor In the case of exceeding the alarm temperature th...

Страница 28: ...range Measurement accuracy Temperature setting range Thermal resistance of the sensor Fuse cartridge O C O C O C O C A 0 90 1 45 80 25 90 6 3 VII Assembly NOTE Installation should be performed by a pr...

Страница 29: ...it cannot replace CH installation project Its aim is to present how the controller may be expanded This heating installation diagram does not include protective elements which are necessary to ensure...

Страница 30: ...e 14 II 12 Fan in sustain mode 15 II 16 Factory settings 15 II 17 Information about the programme 16 III Installation menu 16 III a 1 Switch on 17 III a 2 Set point valve temperature 17 III a 3 Temper...

Страница 31: ...er sensitivity 26 III 14 Language selection 26 IV Service menu 26 V Protections 26 V 1 Temperature alarm 26 V 2 Thermal protection 26 V 3 Automatic sensor control 27 V 4 Protection against boiling of...

Страница 32: ...ST 480 32...

Отзывы: