ST – 480
As an alternative to the temperatures being preset separately for
individual days, the temperatures can also be set collectively, in the
second mode, for the working days (from Monday to Friday) and the
weekend (Saturday and Sunday) separately - Set mode 2.
Monday - Friday; Saturday - Sunday
Similarly to the previous mode it is necessary to select specific times and
required deviations from the temperature preset for the working days
(Monday - Friday) and the weekend (Saturday, Sunday).
Example
Monday - Friday
preset: 3 00 , temp. -10°C (temperature change – 10°C)
preset: 4 00 , temp. -10°C (temperature change – 10°C)
preset: 5 00 , temp. -10°C (temperature change – 10°C)
Saturday - Sunday
preset: 16 00 , temp. 5°C (temperature 5°C)
preset: 17 00 , temp. 5°C (temperature 5°C)
preset: 18 00 , temp. 5°C (temperature 5°C)
In this case, if the preset boiler temperature is 60ºC, the temperature
will drop 10ºC to 50ºC between 3 a.m. and 6 a.m. on each day from
Monday to Friday. However, the temperature will rise 5ºC to 65ºC during
weekend (Saturday, Sunday) between 4 p.m. and 7 p.m.
Step #3:
The user enables one of two preset modes (Mode1, Mode2) or
disables the weekly control option.
Once the mode is enabled the value of the deviation currently set is
displayed on the main page of the controller next to the preset central
heating system temperature. This, additionally, indicates that the weekly
control is active.
Data deletion function is a simple method to remove all previously saved
weekly programme settings to enter new settings.
II.5.
Feeding time
This option is used to set the fuel feeder operation time. The time should
be set according to the fuel being used and the boiler type.
II.6.
Feeding pause
Feeding pause time is used to set the pause time in feeder operation. The
- 9 -