ST-45 User's Manual
With this function, you can set the temperature for central heating pump
and hot consumption water pump activation. (This is the temperature
measured on the boiler). Below the set temperature (-2°C), the pumps
are inoperative, and above the setpoint value, the pumps are activated
but they operate according to the selected mode.
IV.2.Feeder Alarm Temperature
With this protective function, you can set the alarm temperature for the
fuel feeder. If the feeder temperature rises unexpectedly, this can be due
to the presence of fire in the feeder. After the feeder alarm temperature
is reached, the feeder starts to run in order to discharge the burning
material into the furnace.
IV.3.Priority Temperature
With this function, you can set the temperature in the hot consumption
water heating priority. The temperature adjustment range is 50-75°C.
-20-
SERVICE MENU
Exit
Pump Activation Temp
Feeder Alarm Temp
Priority Temp
FEEDER ALARM TEMP
degrees
SERVICE MENU
Exit
Pump Activation Temp
Feeder Alarm Temp
Priority Temp
PRIORITY TEMP
degrees
Содержание ST-45
Страница 1: ...ST 44 USER S MANUAL...
Страница 31: ...TECH 31...
Страница 32: ...ST 45 User s Manual 32...