TECH
No. Specification
Unit
1
Supply Voltage
V
230V/50Hz +/-10%
2
Max. Power Consumption
W
11
3
Ambient Temperature
O
C
10 -
50
4
Central Heating; Hot Consumption Water;
Floor; Circulation - Pump Outlet Load
A
,
0 5
5
Fan Output Load
A
,
0 6
6
Feeder Output Load
A
2
6
7
8
9
10
Temperature Measurement Range
Measurement Accuracy
Temperature Adjustment Range
Sensor Thermal Resistance
Fuse Insert
O
C
O
C
O
C
O
C
A
0 - 85
1
45 - 80
-25 - 100
6,3
VIII.Assembly
ATTENTION:
all assembly works must only be carried out by qualified
persons. During assembly, the device
must be
disconnected (make sure
the power cord is unplugged)!
ATTENTION
:
improper cable connection may damage the regulator!
ATTENTION:
the
ST-45
controller must be built into the boiler so that
the cable connection strips are not accessible.
The regulator may not be operated in a closed-circuit central heating
system. It is necessary to provide for safety valves, pressure valves and
a surge tank in order to prevent water from boiling in the central heating
system.
-27-