TECH
The higher the gear, the higher the speed with 10% being the minimum
and the 100% being the maximum speed of the fan.
Initially, the fan runs always at full speed so that it is possible to start it
with the motor being slightly dusty.
II.9.Operation Mode
With this function, you can select one out of four operation modes.
II.9.a)House Heating
If you select this option, the regulator will switch into the house heating
mode. The central heating pump starts to run above the pump activation
threshold (set to 40°C by default). Below this temperature, the pump is
shut off.
II.9.b)
Water Heater Priority
-9-
MENU
Exit
Blow Force
Operation Mode
Sustain Mode
HOUSE HEATING
C.H. H.C.W.
WATER HEATER PRIORITY
C.H. H.C.W.