4 OPERATION 

To adapt the converter to the meter, the pulses per unit factor specified on the meter must 
be programmed. To do this, the plastic front cover must be removed by unscrewing the four  
screws on the corners. After that, the push buttons will be accessible. 

There are three push buttons with the following functions: 

There are seven options of units: pounds (lb), cubic metres (m

3

), U.S. Gallons (USGAL), litres 

(L),  kilograms (kg), grams (g), and without specific units selected (all units off). The selected 
unit will be flashing on the display (except when no specific units are selected). Use the push 
button marked with the arrow pointing upwards to change from one unit to the next. By 
pushing the two push buttons PROG at the same time (do not keep the push buttons 
pushed) the selected unit will be saved into memory and the next programming screen for 
the k factor will appear. If the RESET push button is pressed then the next programming 
screen for the k factor will appear but the selected unit will not be saved into memory and 
the previous measuring unit will be retained. 

4.1.2  k factor (pulses per unit) 

4.1 Programming 

By pushing the two push buttons PROG at the same time for at least two seconds, the 
display will change to the first stage of the programming mode. 

4.1.1 Measuring 

Units 

 In this screen the measuring units can be programmed.  

Содержание CIP II

Страница 1: ...R MI CIPII Rev 1 english version Series CIP CIP II converter Instructions manual The art of measuring...

Страница 2: ...nd safety with no obligation to update this manual Make sure this manual goes to the end user Keep this manual in a place where you can nd it when you need it In case of loss ask for a new manual or d...

Страница 3: ...error correction 7 6 2 Change of units of measurement 8 7 TECHNICAL CHARACTERISTICS 8 7 1 COVOL input characteristics 9 7 2 Turbine input characteristics 9 8 SAFETY INSTRUCTIONS 10 8 1 Certi cate of c...

Страница 4: ...st screw the connector at the back of the converter onto the connector base of the owmeter previously checking that the sealing gland is correctly situated in the bottom of the connector base The conv...

Страница 5: ...cted Use the push button marked with the arrow pointing upwards to change from one unit to the next By pushing the two push buttons PROG at the same time do not keep the push buttons pushed the select...

Страница 6: ...units the k factor should be programmed as follows 1 litres the k factor will be directly the value on the owmeter label 2 m3 the k factor should be multiplied by 1000 3 U S gallons the k factor shou...

Страница 7: ...when this counter is reset In the above screen the total counter is shown as having over owed once this would be equivalent to a count of 10002501 and the partial counter as having over owed eight tim...

Страница 8: ...om litres to kg we must divide the pulse per litre factor by the density of the liquid to obtain the new factor for programming the CIP II For example if the liquid has a density of 0 9 kg litre the m...

Страница 9: ...ount Due to the presence of a lter to avoid the effects of contact bounce the maximum pulse frequency for the COVOL input is 300 Hz The minimum input frequency is 0 06 Hz 7 2 Turbine input characteris...

Страница 10: ...con rming the quality of production with the standards on the territory of the Customs Union particularly regarding safety requirements and electromagnetic compatibility 9 ADDITIONAL INSTRUCTIONS FOR...

Страница 11: ...it should be grounded through the housing screw as shown in the gure 9 1 3 Maintenance NOTE The cover should never be opened in presence of explosive atmosphere There is no special maintenance for th...

Страница 12: ...12 Local CIP II 10 DIMENSIONS All dimensions in mm...

Страница 13: ...13 Remote CIP II All dimensions in mm...

Страница 14: ...liquid grease or toxic substances The devices sent for repair must enclose the corresponding form which can be lled in via website from the same After Sales section Warranty for repaired or replaced...