1 INTRODUCTION 

The CIP II converter is designed to work with oscillating piston flowmeters (COVOL) and 
turbine flowmeters series TM. 

The circuit is based on a microprocessor that, in function of the programmed pulses per unit 
of volume, totalizes the volume that flows through the meter and shows this value on the 
display. The CIP II has two volume totalizers, one that can be reset (partial) and the other 
that cannot be reset (total).  

This instrument is battery powered and does not require any wiring. This makes its 
installation very easy. 

2 MODELS 

3 ELECTRICAL 

CONNECTION

 

No electrical connections are required for the local indication models. Just screw the 
connector at the back of the converter onto the connector base of the flowmeter, previously 
checking that the sealing gland is correctly situated in the bottom of the connector base. The 
converters are supplied already configured for the type of flowmeter to be used (COVOL or 
TM). 

Connections are the following: 

 Terminal 

COVOL 

Turbine 

 1 

Reed 

Ground 

 2 

Reed 

Live 

coil 

 

- - - 

Live coil 

For the remote wall mounting models, the connections should be made as follows: 

COVOL oscillating piston flowmeter 

Flowmeter terminal N. 

Connection 

CIP II terminal N. 

 

 1 

  Reed 

  1 

 

 2 

  Reed 

  2 

TM turbine flowmeter 

Flowmeter terminal N. 

Connection 

CIP II terminal N. 

 

 1 

  Shield 

  1 

 

 2 

  Live 

Coil  2 

 

 3 

  Live 

Coil  3 

The earth terminal of the CIP II connector should not be connected. 

CIP II 

 

 

 

C   COVOL input 

 

 

T   TM input 

 

Local mounting on the flowmeter (IP65)  

 

Remote wall mounting (IP65)  

 

 

 

 

 

Содержание CIP II

Страница 1: ...R MI CIPII Rev 1 english version Series CIP CIP II converter Instructions manual The art of measuring...

Страница 2: ...nd safety with no obligation to update this manual Make sure this manual goes to the end user Keep this manual in a place where you can nd it when you need it In case of loss ask for a new manual or d...

Страница 3: ...error correction 7 6 2 Change of units of measurement 8 7 TECHNICAL CHARACTERISTICS 8 7 1 COVOL input characteristics 9 7 2 Turbine input characteristics 9 8 SAFETY INSTRUCTIONS 10 8 1 Certi cate of c...

Страница 4: ...st screw the connector at the back of the converter onto the connector base of the owmeter previously checking that the sealing gland is correctly situated in the bottom of the connector base The conv...

Страница 5: ...cted Use the push button marked with the arrow pointing upwards to change from one unit to the next By pushing the two push buttons PROG at the same time do not keep the push buttons pushed the select...

Страница 6: ...units the k factor should be programmed as follows 1 litres the k factor will be directly the value on the owmeter label 2 m3 the k factor should be multiplied by 1000 3 U S gallons the k factor shou...

Страница 7: ...when this counter is reset In the above screen the total counter is shown as having over owed once this would be equivalent to a count of 10002501 and the partial counter as having over owed eight tim...

Страница 8: ...om litres to kg we must divide the pulse per litre factor by the density of the liquid to obtain the new factor for programming the CIP II For example if the liquid has a density of 0 9 kg litre the m...

Страница 9: ...ount Due to the presence of a lter to avoid the effects of contact bounce the maximum pulse frequency for the COVOL input is 300 Hz The minimum input frequency is 0 06 Hz 7 2 Turbine input characteris...

Страница 10: ...con rming the quality of production with the standards on the territory of the Customs Union particularly regarding safety requirements and electromagnetic compatibility 9 ADDITIONAL INSTRUCTIONS FOR...

Страница 11: ...it should be grounded through the housing screw as shown in the gure 9 1 3 Maintenance NOTE The cover should never be opened in presence of explosive atmosphere There is no special maintenance for th...

Страница 12: ...12 Local CIP II 10 DIMENSIONS All dimensions in mm...

Страница 13: ...13 Remote CIP II All dimensions in mm...

Страница 14: ...liquid grease or toxic substances The devices sent for repair must enclose the corresponding form which can be lled in via website from the same After Sales section Warranty for repaired or replaced...

Отзывы: