background image

 

Thank you for choosing a product from Tecfluid S.A.  

This instruction manual allows the installation, configuration, 
programming and maintenance. It is recommended to read it before 
using the equipment. 

• 

This document shall not be copied or disclosed in whole or in any 
part by any means, without the written permission of Tecfluid S.A. 

• 

Tecfluid S.A. reserve the right to make changes as deemed 
necessary at any time and without notice, in order to improve the 
quality and safety, with no obligation to update this manual. 

• 

Make sure this manual goes to the end user. 

• 

Keep this manual in a place where you can find it when you need 
it. 

• 

In case of loss, ask for a new manual or download it directly from 
our website 

www.tecfluid.com

  Downloads section. 

• 

Any deviation from the procedures described in this instruction 
manual, may cause user safety risks, damage of the unit or cause 
errors in the equipment performance. 

• 

Do not modify the equipment without permission. Tecfluid S.A. are 
not responsible for any problems caused by a change not 
allowed. If you need to modify the equipment for any reason, 
please contact us in advance. 

PREFACE 

WARNINGS 

Содержание CIP II

Страница 1: ...R MI CIPII Rev 1 english version Series CIP CIP II converter Instructions manual The art of measuring...

Страница 2: ...nd safety with no obligation to update this manual Make sure this manual goes to the end user Keep this manual in a place where you can nd it when you need it In case of loss ask for a new manual or d...

Страница 3: ...error correction 7 6 2 Change of units of measurement 8 7 TECHNICAL CHARACTERISTICS 8 7 1 COVOL input characteristics 9 7 2 Turbine input characteristics 9 8 SAFETY INSTRUCTIONS 10 8 1 Certi cate of c...

Страница 4: ...st screw the connector at the back of the converter onto the connector base of the owmeter previously checking that the sealing gland is correctly situated in the bottom of the connector base The conv...

Страница 5: ...cted Use the push button marked with the arrow pointing upwards to change from one unit to the next By pushing the two push buttons PROG at the same time do not keep the push buttons pushed the select...

Страница 6: ...units the k factor should be programmed as follows 1 litres the k factor will be directly the value on the owmeter label 2 m3 the k factor should be multiplied by 1000 3 U S gallons the k factor shou...

Страница 7: ...when this counter is reset In the above screen the total counter is shown as having over owed once this would be equivalent to a count of 10002501 and the partial counter as having over owed eight tim...

Страница 8: ...om litres to kg we must divide the pulse per litre factor by the density of the liquid to obtain the new factor for programming the CIP II For example if the liquid has a density of 0 9 kg litre the m...

Страница 9: ...ount Due to the presence of a lter to avoid the effects of contact bounce the maximum pulse frequency for the COVOL input is 300 Hz The minimum input frequency is 0 06 Hz 7 2 Turbine input characteris...

Страница 10: ...con rming the quality of production with the standards on the territory of the Customs Union particularly regarding safety requirements and electromagnetic compatibility 9 ADDITIONAL INSTRUCTIONS FOR...

Страница 11: ...it should be grounded through the housing screw as shown in the gure 9 1 3 Maintenance NOTE The cover should never be opened in presence of explosive atmosphere There is no special maintenance for th...

Страница 12: ...12 Local CIP II 10 DIMENSIONS All dimensions in mm...

Страница 13: ...13 Remote CIP II All dimensions in mm...

Страница 14: ...liquid grease or toxic substances The devices sent for repair must enclose the corresponding form which can be lled in via website from the same After Sales section Warranty for repaired or replaced...

Отзывы: