This process will guide you to restart your process after the coater plexi-glass cover
has opened. If this panel is opened during operational, it will shut down the
Coater
Clutch, UV Fluid pump
and the
Feeder air pump.
NEVER leave the rollers engaged for more than 20 minutes, when not in operation.
This will cause a flat spot on the rubber roller and affect coating quality.
1)
After shutdown remove or make necessary fixes.
2)
If repair takes more than 20 minutes, disengage the metering, impression roller and
the doctor blade.
Refer to section 13 paragraphs 9-10
.
3)
Refer to
section 15 paragraphs 1-8
Fast Stop Process.
Please note some of these steps will apply to Offline and Feeder system.
You have now completed the Restart Process.
Note:
After opening the plexi-glass cover
an error message will display on the
touch screen.
This is a Warning message to let you
know a safety interlock door is open.