background image

Installation Manual

HPNFC-RT

BocaFlasher.com

1 of 7

REV 04-2019

IP60

Dry Listing

Damp Listing

IP65

IP68

Wet Listing

INTRODUCTION:

The Boca HPNFC-RT is a line voltage fixture that eliminates the need for secondary transformers, making installation contractor 

friendly. The housing is a clear anodized aluminum with a durable finish making it weather and abrasion resistant. It is UL Listed 

 

for dry, damp or wet location (model dependent). See layout drawings for model provided.

1.  Input Voltage: 90-120VAC, 230-277VAC

2.  Total linear ft per 20A breaker: HO8 = 175’ 

 

Total linear ft per 20A breaker: HO6 = 200’ 

 

Total linear ft per 15A breaker: HO8 = 130’ 

 

Total linear ft per 15A breaker: HO6 = 150’

3.  Input Current: HO8 = 114mA RMS per linear ft. 

 

Input Current: HO6 = 95mA RMS per linear ft.

ELECTRICAL SPECIFICATIONS:

Fixtures must be installed by a qualified and licensed electrician 

in accordance with all national, state and local electrical codes 

and regulations. If any part of this manual does not meet the 

necessary codes and regulations, contact the factory for more 

information before attempting to install.

WARNING: DO NOT LIFT FIXTURE BY CABLES. Do not attempt to install or use the HPNFC-RT fixture without 

reading the installation instructions and safety labels completely.

This could result in permanent damage to both the fixture and the cables. Damage resulting from grasping cables and/or 

putting undue pressure on the cable connections will not be covered under the warranty!

FAILURE TO ADHERE TO THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR PROPERTY DAMAGE. 

DO NOT MODIFY, ALTER OR ATTEMPT TO SERVICE THE HPNFC-RT DOING SO WILL VOID THE WARRANTY.

Max Temp: 55°C

Min. Temp: -40°C

Storage:

  Store in a dry, well-ventilated area when product is not in 

use. Keep the electrical cord away from heated surfaces 

when in use or not in use. If cord shows signs of damage

 

do not use, return product to manufacturer.

Cleaning: 

  Dry and Damp (IP65) Rated Fixtures: 

 

To clean surface use a soft damp cloth.

  Wet (IP68) Rated Fixtures: 

 

To clean surface use a soft cloth with mild soap and water.

MAINTENANCE:

Содержание HPNFC-RT

Страница 1: ...ions If any part of this manual does not meet the necessary codes and regulations contact the factory for more information before attempting to install WARNING DO NOT LIFT FIXTURE BY CABLES Do not attempt to install or use the HPNFC RT fixture without reading the installation instructions and safety labels completely This could result in permanent damage to both the fixture and the cables Damage r...

Страница 2: ...Using a chalk line or laser mark a line on the flat surface where the clips are to be mounted Align each clip to the chalk line using the same reference point on each clip clip edge or hole and space the clips according to the length of each fixture see figure A Clip placement Boca Flasher recommends clips to be installed 1 5 from end cap 2 Snap in the first light fixture into the clips see sectio...

Страница 3: ...making a 90 bend Screw Information 1 Screws not provided by Boca Flasher 2 Boca Flasher recommends wide washer flat head Philips 8 screw not to exceed 418 in diameter 3 Length of screw will vary depending on mounting surface 4 For outdoor installations installer should use a screw with weatherproof coating 1 INSTALL CLIPS INTO SUBSTRATE 1 Fixed Clips 1a 1b 3 3 Arc and 6 Arc Bracket Installation 1a...

Страница 4: ...rst notch of the fixture 2b Fixture will pivot on notch as it is pushed down 2c Clip will securely snap into place 2d If using the Swivel Clip or Arc Bracket loosen the screw where the clip and swivel bracket meet to adjust angle of the fixture SNAP 3 CLIP POSITIONING 3a Fixed Mounting Clip 3c Swivel Mounting Clip 3b Arc Mounting Clip ...

Страница 5: ...ark a line on the flat surface where the 2 clips for the 2nd fixture are to be mounted this fixture can be placed on a slightly different plane as long as the cord between the 2 fixtures is long enough Also this fixture can be placed at a different angle than the first fixture see figure 4 5 Snap in the 2nd light fixture into the clips see section 2 installing fixtures into clips 6 Continue this p...

Страница 6: ...st lock cables in order shown on job specific drawings 5c Push together and then twist until completely connected and sealed if outdoors Add tape to twist locks Place thumb over tape at starting point and PULL around connector area until tape overlaps itself 6a CONNECT FIXTURES TO POWER RECOMMENDED INSTALL OPTION 1 Exterior version shown 6b CONNECT FIXTURES TO POWER RECOMMENDED INSTALL OPTION 2 ...

Страница 7: ...bles away from heated surfaces Never drop or insert any object into any opening Do not operate where aerosol spray products are being used or where oxygen is being administered 3 WARNING Do not attempt to install or use the HPNFC RT without reading the installation instructions and safety labels Failure to adhere to these instructions could result in serious injury or property damage 4 Do not modi...

Отзывы: