6-1
6. OPTIONAL EQUIPMENT
EO18-33014
6.1 HOW TO USE THE BATTERY CHARGER (B-SP2D-CHG-QM)
6. OPTIONAL EQUIPMENT
6.1 HOW TO USE THE BATTERY CHARGER (B-SP2D-CHG-QM)
WARNING!
1.
The B-SP2D-CHG battery charger is exclusively used for the B-SP2D-BT lithium-ion battery pack.
DO NOT charge any other battery packs, or explosion, combustion, heat may result.
2.
If the battery charger gives out smoke, bad smell, or extraordinary heat, unplug the power cord from
the outlet immediately. Failure to do this may cause fire or electric shock.
1)
Connect the AC power cord to the charger.
2)
Connect the AC plug to a wall outlet.
3)
Install the battery pack.
The CHARGE lamp will light and charging will begin. The CHARGE lamp indicates how much the battery pack
is charged.
4)
After charging is completed, remove the battery pack from the battery charger.
5)
Disconnect the power cord from the AC outlet.
CHARGE lamp
State
OFF
Unconnected.
Red
Charged.
Green
Completed.
Blinking red
Abnormal state
1
2
3
Battery Pack (B-SP2D-BT)
Battery Charger (B-SP2D-CHG)
AC Power Cord
CHARGE Lamp
NOTE:
Since the power cord set is not enclosed in this battery charger unit, please purchase an approved one
which meets the standard for each country from your Authorized TOSHIBA TEC representative. For
details, please refer to the B-SP2D-CHG Owner's Manual.