6-12
EM18-33017
6. DIAG. TEST OPERATION
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
< 1
D I A G N O S T I C
V 1 . O A
>
T H
R M A L
H E A D
C H E C K
E
C H
C K I N G
E
N O
M A L
E N D
R
H E
D
E R R O R
A
Press the [PAUSE] key twice.
Press the [PAUSE] key.
Head broken element check
takes about 10 seconds.
Press the [PAUSE] key.
(See NOTE 1 and 2.)
Press the [FEED] key twice.
NOTES:
1.
If the head broken element check results in ‘HEAD ERROR’, the print head must
be replaced after referring to Section 2.5 Replacing the Print Head.
2.
After replacing the print head, clear the maintenance counter as described in
Section 6.6.1 and perform a test print in Section 6.4 TEST PRINT MODE.
6.2 SELF TEST MODE
6.2.3
Head Broken Element Check
The printer automatically performs the head broken element check. The result of the head broken
element check is indicated in the display.