7.
CLEANING, LUBRICATION, AND STORAGE
For best performance and minimum downtime, the applicator should be cleaned daily and monthly, and
inspected, lubricated, and stored as indicated in Instruction Sheet
8.
REVISION SUMMARY
Revised Section 5.4 and added Air Feed Modules PN 2844940-1 and PN 2844940-2 (Section 5.4.B.)
Corrected reference in Paragraph 5.1.A.5.
In paragraph 5.4.B added the following Caution: Do not tamper with the set screws located in the air
feed valve assembly, and NOTE: The life of the piston seal can be extended by applying either
MAGNALUBE-G or Parker Super O-Lube to the outer diameter of the air cylinder piston shaft.
Corrected reference in Paragraph 6.4.3.
Added new Figure 15, renumbered subsequent figures and adjusted references accordingly.