5.5.
Adjusting the strip guide
Disconnect electrical power when performing maintenance or repair on this equipment.
1. Turn off the machine.
2. Disconnect the power cord.
3. Raise the ram.
4. Remove the applicator from the machine as described in section 3, INSTALLING AND REMOVING
5. Remove the ram assembly from the applicator.
6. Remove the two nuts holding the springs in place on the terminal drag plate (Figure 14).
Figure 14: Adjusting the strip guide
1
Terminal strip aligned with anvil
4
Terminal drag plate
2
Strip hold-down plate (if present)
5
Drag spring and retaining nut (2 places)
3
Lower strip guide screw (6 places)
6
Lower strip guide
7. Remove the drag plate and springs.
8. Loosen (but do not remove) the six screws securing the lower strip guide.
9. With a terminal strip in place, adjust the guides to align and center the strip over the anvil.