Crimp Height
Adjustment Wheel
Wire Crimper
Tool
Holder
Crimper
Bolt
Manual Precision Adjustment
Mechanism on the Terminator
408-32027
8 of 11
Rev A
Figure 7
4. Lower the terminal drag.
5. Depress and release the manual over-ride button
on the air feed valve located on the back of the
terminator until the terminal is located above the
anvil. See Figure 8.
6. Determine the direction of adjustment required to
center the terminal over the anvil.
7. Loosen the adjustment locking screw.
8. Turn the adjustment screw to make an
adjustment. See Figure 9.
Manual Over-Ride Button
Figure 8
Adjustment Locking Screw
Adjustment Screw
Stroke Clamp
Figure 9
9. Tighten the adjustment locking screw.
NOTE
i
For side feed applicators: Turning the adjustment
screw clockwise will move the terminal to the left
on the next feed stroke. For end feed applicators:
Turning the adjustment screw clockwise will move
the terminal toward the rear of the anvil on the next
feed stroke.
10. Raise the terminal drag, lift the feed finger, and
pull the terminal strip back and repeat steps 3
through 7 until the terminal is centered over the
anvil.
11. If the feed finger stroke is incorrect, loosen the
stroke clamp (Figure 9) and move the clamp closer
to the air cylinder for less stroke and further from the
cylinder for more stroke.
12. Tighten the clamp and check the feed.
5.3. Strip Guide Plate and Feed Pawl Adjustments
(Side-
Feed Through-Splice Applicators Only)
This procedure moves the plate on which the strip
guides are mounted. Since the terminal strip is fed into
the applicator between the strip guides, it is moved
front and back over the anvil as the strip guides are
moved.
The adjustment of the feed pawl to match any change
in the position of the front strip guide is also described
here.
DANGER
STOP
To avoid personal injury, be SURE power to the
terminator is turned "off" and the power cord is
disconnected before removing the applicator.
1. With the power to the terminator "off," and the
power cord disconnected, open the terminator