background image

408-32027

5 of 11

Rev A

3. APPLICATOR INSTALLATION AND REMOVAL

CAUTION

!

With the applicator in the machine, NEVER attempt 

to cycle machine under power WITHOUT terminals 

properly loaded, as described in Section 4; 

otherwise, the tooling may be damaged.

3.1. Applicator Installation

DANGER

STOP

To avoid personal injury, be SURE the terminator is 

turned off and power to the machine is 

disconnected BEFORE installing or removing the 

applicator.

A. Tool Holder Installation

To properly install Through-Splice Applicator first 
install the tool holder. 

1. Position the tool holder on the bottom of the 
terminator ram using the two locating pins shown in 
Figure 4.

2. Secure the the tool holder into position with two 
cap screws.

B. Applicator Base (Lower Tooling) Installation

Align the applicator base to the terminator and the tool 
holder and secure the base plate to the terminator 
base as follows:

1. Align the lower tooling to the upper tooling (tool 
holder with the crimper installed) In the side-to-side 
direction.

DANGER

STOP

To avoid personal injury, be SURE the terminator is 

turned off and power to the machine is 

disconnected BEFORE installing or removing the 

applicator. Lower the ram by removing the power 

cord from the back of the terminator.  Insert a hex 

wrench into back of the gearbox and turn the drive 

sprocket.

a. Place the base plate of the applicator onto the 
base portion of the terminator and loosely install 
two 6mm screws.

b. Double a piece of paper over the anvil and 
lower the terminator ram and tool holder so that 
the crimper engages with the anvil.

c. Try to rotate the lower portion of the applicator. 
It should not have any movement. If side-to-side 
movement is present, lower the ram and crimper 
until the base plate does not move.

If the ram is at the bottom-dead-center position 
and there is still movement, the crimper must 
be adjusted. Refer to Paragraph 5.1, Crimp 
Height Adjustment.

If the lower portion has no movement then it is 
properly located side to side.

2. Align the lower tooling to the upper tooling (tool 
holder with the crimper installed) In the

 front-to-

back

 direction.

NOTE

i

The lower tooling on the base plate is located 

properly when the bellmouth on the product is 

within the specified range.

3. Tighten two 6mm screws securing the applicator 
base to the terminator base.

4. IInstall the wrap-around guard  to the applicator 
with two mounting screws. 

5. Be sure the appropriate plexi-glass guard is 
installed on the terminator.

Refer to customer manual 409-10204 for hand-cycling 
instructions.

3.2. Applicator Removal

DANGER

STOP

To avoid personal injury, Be SURE power to the 

machine is turned "off" (or power cord is 

disconnected) BEFORE installing or removing the 

applicator.

1. Turn machine "off" and disconnect power cord.

2. Remove the wrap-around guard by removing the 
two mounting screws. Refer to Figure 6. 

3. Remove the product strip from the applicator. 

4. Remove two 6mm screws that secure the 
applicator base to the terminator.

5. Slide the applicator base clear.

6. Remove two screws that secure the tool holder to 
the terminator ram.

7. To store the applicator, refer to Section 8, 
APPLICATOR STORAGE.

4. APPLICATOR LOADING AND UNLOADING

DANGER

STOP

To avoid  personal injury, be SURE the terminator is 

turned off and power to the machine is 

disconnected BEFORE loading or unloading the 

applicator.

4.1. Terminal Strip Loading

Before loading terminal strip in applicator, be SURE 
the installed applicator is the right one for terminal to 
be applied. Compare terminal number on reel with 
numbers listed on applicator parts list.

1. Turn "off" and disconnect power to the terminator.

2. Be sure ram assembly is all the way up. If 
necessary, hand-cycle machine to raise the ram. 
(Refer to customer manual 409-10204 for hand-
cycling instructions.)

3. Open the guard doors of the terminator.

4. Raise stock drag by turning terminal drag (drag 
release lever) upward. 

Содержание AMP 5k/40 CE

Страница 1: ...Terminators apply strip terminals to pre stripped wires Each applicator accepts the strip form of certain terminals which are identified on the applicator parts list and exploded view drawing Applicat...

Страница 2: ...d to allow access to both sides of the crimper for through splice type applications Refer to Figure 3 These guards work together with the applicator guards to protect the operator The left and right g...

Страница 3: ...inal from the strip The wire crimp is easily adjusted providing an array of different wire crimp sizes NOTE i All AMP 5K 40 CE Through Splice Terminators are equipped with a precision adjust feature T...

Страница 4: ...strip and the terminal holder keeps the terminal from raising during the crimping and shearing process The anvil the front shear holder the rear shear holder if used the terminal support and the strip...

Страница 5: ...r must be adjusted Refer to Paragraph 5 1 Crimp Height Adjustment If the lower portion has no movement then it is properly located side to side 2 Align the lower tooling to the upper tooling tool hold...

Страница 6: ...ard the stock drag and the open side up 6 Raise feed pawl and continue to feed terminal strip until LEAD terminal is over anvil and feed pawl engages hole in carrier strip 7 Turn terminal drag downwar...

Страница 7: ...justments as follows A Minor Crimp Height Adjustments Minor adjustments can be made using the manual adjust that is on the terminator The total adjustment range using this feature is approximately 018...

Страница 8: ...oward the rear of the anvil on the next feed stroke 10 Raise the terminal drag lift the feed finger and pull the terminal strip back and repeat steps 3 through 7 until the terminal is centered over th...

Страница 9: ...er strip but be sure the strip guides are parallel and that the terminal strip can move freely with a minimum of side clearance Retighten the screws NOTE i If feed pawl is not aligned with the front s...

Страница 10: ...the anvil is replaced the front shear and holder must be re aligned See Paragraph 5 6 A 6 Re align crimpers 6 2 Floating Shear Replacement Side Feed Through Splice Applicators Only NOTE i It is not n...

Страница 11: ...onnected before removing the applicator 1 With the power to the terminator off and the power cord disconnected open the terminator guard doors and remove the applicator as described in Paragraph 3 2 N...

Отзывы: