INSTRUCTION MANUAL
RWS1000B
•
1500B Series
TDKLambda
<Page>
/S
CN83 :
Remote ON/OFF control
CN84 :
Remote ON/OFF control
Standby supply
* CN83, CN84 Connector (JST)
Each other terminals are same as standard model.
These are connected by short pieces at time of shipment.
CN83 : "+Vm" terminal (Pin No.1) to "+S" terminal (Pin No.2)
"Vm" terminal (Pin No.9) to "S" terminal(Pin No.10)
CN84 : "+R" terminal (Pin No.3) to "+STB" terminal (Pin No.6)
"R" terminal (Pin No.4) to "STB" terminal (Pin No.10)
7/23
No. Configuration
Function
1
+Vm
Output monitor terminal (+V). Internally connected to +Output terminal.
(+Vm terminal can not supply load current.)
2
+S
Remote sensing terminal for +output.
(For remote sensing function, which compensates for line drop between
power supply terminals and load terminals. Connect to +Vm terminal when
remote sensing function unnecessary.)
3
+R
Remote ON/OFF control terminal.
4
R
GND for Remote ON/OFF control terminal.
5
NC
No cnnection
6
NC
No cnnection
7
NC
Do not connect. If connected may cause miss operation.
8
NC
No cnnection
9
Vm
GND for Output monitor terminal. Internally connected to Output
terminal. ( Vm terminal can not supply load current.)
10
S
Remote sensing terminal for output side.
(For remote sensing function, which compensates for line drop between
power supply terminals and load terminals. Connect to Vm terminal when
remote sensing function unnecessary.)
No. Configuration
Function
1
NC
No cnnection
2
NC
No cnnection
3
+R
Remote ON/OFF control terminal.
4
R
GND for Remote ON/OFF control terminal.
5
+STB
Standby supply (5V/1A).
6
+STB
Standby supply (5V/1A).
7
NC
Do not connect. If connected may cause miss operation.
8
NC
No cnnection
9
STB
GND for Standby.
10
STB
GND for Standby.
9
7
5
3
1
8
6
4
2
10
CN83
9
7
5
3
1
8
6
4
2
10
CN84