INSTRUCTION MANUAL
RWS1000B
•
1500B Series
TDKLambda
<Page>
/R, /RFO, /S
• Remote ON/OFF control
Connect voltage between " +R" terminal (Pin No.3) and "R" terminal (Pin No.4) for remote
ON/OFF control. (ON/OFF control lines shall be twisted.)
/FO, /RFO
•
Parallel operation
Connecting PC to PC terminal
(Pin No.8)
and COM to COM terminal
(Pin No.7)
, the current balancing
function activates and output current of each power supply is equivalently supplied to load. Wires to
PC terminals, COM terminals shall be as short as possible and same length and twisted.
•
PF signal output
PF signal is open collector output. Use as shown below. (Signal lines shall be twisted.)
11/23