7. Mounting Method
71. Mounting Method
(1) These models are forced air cooling type power supply. The power supply has ventilating holes. Keep a
space more than 50mm from the front side and back side of the power supply to the peripheral parts.
Standard and option model exclude /RF also keep a space more than 5mm between other surfaces and the
peripheral parts. / RF does not require a space.
The power supply may cause damage when it intake conductive material, dust and liquid. Never use
in the dusty environment.
・
Standard and option model exclude /RF
・
/RF
(2) The maximum allowable penetration of mounting screws is 5mm.
Incomplete thread of mounting screw should not be penetrated.
(3) Recommended torque for mounting screw.
M4 screw : 1.27N·m (13.0kgf·cm)
72. Output Derating according to the Mounting Directions
The standard mounting is direction (A). Direction (B), (C) and (D) are also possible. Please contact us for
other mounting directions.
Never use as mounting direction (E) and (F) shown below.
Refer to the output derating below, load (%) is percent of maximum output current value in a rated output
voltage.
■ Mounting direction
(A) Standard Mounting
(C )
(D)
(E) Not Possible
(B)
(F) Not Possible
20/23
Top
Fan
Front side
Output Terminal
Back side
More than 50mm
More than 50mm
Air flow
More than 5mm
TERMINAL
INPUT
Front side
Back side
Air flow
Side
Fan
Output Terminal
More than 5mm
Top
Fan
Front side
Output Terminal
Back side
More than 50mm
More than 50mm
Air flow
Front side
Back side
Air flow
Side
Fan
Output Terminal