6­8. Output Ripple 

&

Noise

The standard specification for maximum ripple value is measured according to measurement circuit specified 
by JEITA­RC9131C. When load lines are longer, ripple will becomes larger. In this case, electrolytic capacitor,
film capacitor, etc. might be necessary to use across the load terminal. 
The output ripple cannot be measured accurately if the probe ground lead of oscilloscope is too long.

6­9. Series Operation

For series operation, either method (A) or (B) is possible. 

Method (A)

Method (B)

Note : E nsure  that  all  units  must  be  in  operation.  (Never  use  in  condition  that  one  of  the  units  is  not 

operated.)
When connected the bypass diode, please select a bypass diode with maximum forward current 
rating  more  than  output  load  current.  And  maximum  reveres  voltage  must  withstand  each  power 
supply output voltage.

13/23

Coaxial Cable

1.5 m  50

Ω

C2

+

Load

150mm

C1

R1

C3

Oscilloscope

Power

Supply

Bandwidth :  20 MHz

C1 : 0.1uF     Cap., Film
C2 : 47uF      Cap., Elect.
C3 : 4700pF  Cap., Ceramic
R1 : 50

Ω

Содержание RWS 1500B Series

Страница 1: ...roduct nor remove the cover as you might get an electric shock or might damage the product We will not be held responsible after the product has been modified changed or dis assembled Do not use this...

Страница 2: ...gn matter or dust there is possibility of product failure or malfunction Provide countermeasure for prevention of lightning surge voltage as there is risk of damage due to abnormal voltage Connect tog...

Страница 3: ...ations of Foreign Exchange and Foreign Trade Control Act Catalogue contents of the instruction manual may be changed without a prior notice Refer to latest catalogue or instruction manual Reproduction...

Страница 4: ...ew V Output terminal 62 5A max terminal M5 screw V Output terminal 62 5A max terminal M5 screw Output voltage adjustment trimmer Output monitoring indicator Green LED Terminal cover 1 Terminal cover 2...

Страница 5: ...Output monitor terminal V Internally connected to Output terminal Vm terminal can not supply load current 2 S Remote sensing terminal for output For remote sensing function which compensates for line...

Страница 6: ...As the output voltage drops or FAN stop and AC input voltage down PF signal will be High 6 PF GND for PF signal 7 COM Current balance terminal For current balancing in parallel operation 8 PC Current...

Страница 7: ...terminal when remote sensing function unnecessary 3 R Remote ON OFF control terminal 4 R GND for Remote ON OFF control terminal 5 NC No cnnection 6 NC No cnnection 7 NC Do not connect If connected ma...

Страница 8: ...500B 30A 8 23 COM PC Line Filter Rectifier Inrush Current Limit Circuit Filter Control Circuit L N OCP Circuit Photo coupler Rectifier Filter Input 85 265VAC V Output S S V Vm Vm R R R Remote ON OFF C...

Страница 9: ...n 0 5V Output off This sequence is using external voltage 3 Target option FO RFO 4 Target option S 9 23 PF PF Signal 3 Open collector 0V Vout 0V Input on Input off Input on Input off OVP point 1 Input...

Страница 10: ...No 1 and S terminal Pin No 10 to Vm terminal Pin No 9 with the attached short pieces Short pieces are mounted at time of shipment Recommended torque M3 5 screw 1 0N m 10 2kgf cm 1 6N m 16 3kgf cm M5 s...

Страница 11: ...to COM terminal Pin No 7 the current balancing function activates and output current of each power supply is equivalently supplied to load Wires to PC terminals COM terminals shall be as short as poss...

Страница 12: ...OVP remove the input of power supply for a few minutes and then re input Or use Remote ON OFF reset on option model R and RFO only Remote OFF to ON In addition the setting value of OVP is fixed and n...

Страница 13: ...the probe ground lead of oscilloscope is too long 6 9 Series Operation For series operation either method A or B is possible Method A Method B Note Ensure that all units must be in operation Never us...

Страница 14: ...valently supplied to load Wires to PC terminals COM terminals shall be as short as possible and same length and twisted 1 Adjust the output voltage of each power supply to be same value within 1 2 Use...

Страница 15: ...C between output and R PF STB terminal each for 1 minute When testing withstand voltage set current limit of withstand voltage test equipment at 20mA The applied voltage must be gradually increased fr...

Страница 16: ...M PC PF PF CN83 or CN84 L N V V Withstand Voltage Tester Input Term Output Term CN83 or CN84 L N V V Vm S Vm S R R COM PC PF PF Output Term Input Term Withstand Voltage Tester Vm S Vm S R R STB STB CN...

Страница 17: ...Please check the voltage between Output and terminal If the voltage exceeding withstand voltage please add external capacitor to Output and It can decrease the voltage On the other hand no need to che...

Страница 18: ...and RFO Power Fail PF signal will turn High level to indicate the abnormal status when the output voltage becomes Less than 80 of rated value caused by either the drop or brownout of the input voltage...

Страница 19: ...tion OVP is inverter shut down method and manual reset type OVP function operates within 105 170 When OVP triggers the output will be shut down To reset OVP remove the input of power supply for a few...

Страница 20: ...mplete thread of mounting screw should not be penetrated 3 Recommended torque for mounting screw M4 screw 1 27N m 13 0kgf cm 7 2 Output Derating according to the Mounting Directions The standard mount...

Страница 21: ...e Load is percent of maximum output current value in a rated output voltage 21 23 Mounting A D Load Mounting A D 20 50 100 60 60 Ta C 0 20 40 60 80 100 120 20 10 0 10 20 30 40 50 60 70 80 Load Ta 60 8...

Страница 22: ...mended Recommended wire type and crimp type terminal vary depending on use conditions Choice most appropriate wire type and crimp type terminal by refering to wire maker recommended allowable current...

Страница 23: ...cluding that the unit is at fault Before concluding that the unit is at fault make the following checks 1 Check if the rated input voltage is connected 2 Check if the wiring of input and output is cor...

Отзывы: