5.5 LAN Page
This page and its subpages allow you to view and configure the module’s LAN settings.
5.5.1 LAN
➔
Configure Page
When the “LAN” tab is selected, the “Configure” panel opens:
The following settings are shown on the “LAN
➔
Configure” web page:
IP Address Source: Displays the way the IP address was selected. Options are
DHCP/Auto-IP and Static IP.
IP Address: Displays the IP address assigned to the module through either DHCP,
Auto-IP or Static IP sources.
Subnet Mask: Displays the subnet mask assigned to the module through either
DHCP, Auto-IP or Static IP.
Default Gateway: Address of the network router to allow the module to
communicate outside of the local subnet.
DNS Server: Address of the server running the Domain Naming Service. This is
used for hostname addressing.
Hostname: The module hostname may be used instead of the IP address to
create a communication link. The default hostname is derived from the model
and serial number (see section 3.5) or it may be changed in the LAN
➔
Configure
➔
Modify web page (section 5.5.2).
Description: By default, this is “TDK-LAMBDA HFE-LAN last 3 digits of serial number”,
but it may be changed in the LAN
➔
Configure
➔
Modify web page (section 5.5.2).
Controller Access: The “One Client Only” setting is the default setting for the
highest networking security. This setting allows only one TCP socket or VISA
connection to be open at a time. It disables the connectionless UDP sockets.
See section 5.5.2.
Fig 8. LAN Configuration