7.6 Error Messages
The power supply will return error messages for illegal commands and illegal programming
parameters. Refer to Table 7-1 for programming error messages and Table 7-2 for
command error messages.
Table 7-1: Programming error messages
Error Code
Description
E01
Returned when program voltage (PV) is programmed above acceptable range.
Example: PV above ‘105% of supply rating’ or ‘PV above 95% of OVP setting’.
E02
Returned when programming output voltage below UVL setting.
E04
Returned when OVP is programmed below acceptable range.
Example: OVP less than ‘5% of supply voltage rating’ plus ‘voltage setting’.
E06
Returned when UVL is programmed above the programmed output voltage.
E07
Returned when programming the Output to ON during a fault shut down.
Table 7-2: Commands error messages
Error Code
Description
C01
Illegal command or query
C02
Missing parameter
C03
Illegal parameter
C04
Checksum error
C05
Setting out of range