42
83507013 Rev G
3.9.6 Making the Load Connections
WARNING
Hazardous voltages may exist at the outputs and the load connections when
using a power supply with a rated output greater than 40V. To protect personnel
against accidental contact with hazardous voltages, ensure that the load and its
connections have no accessible live parts. Ensure that the load wiring insulation
rating is greater than or equal to the maximum output voltage of the power supply.
CAUTION
Ensure that the load wiring mounting hardware does not short the output
terminals. Heavy connecting cables must have some form of strain relief to
prevent loosening the connections or bending the bus-bars.
6V to 60V Models
Refer to Fig.3-5 for connection of the load wires to the power supply bus-bars and to
Fig.3-6 for mounting the bus-bars shield to the chassis.