9
83507013 Rev G
PARTS SUBSTITUTIONS & MODIFICATIONS
Parts substitutions and modifications are allowed by authorized TDK-Lambda Americas Inc. service
personnel only. For repairs or modifications, the instrument must be returned to an authorized TDK-
Lambda Americas Inc. service facility.
SAFETY INSTRUCTIONS
ENVIRONMENTAL CONDITIONS
The Genesys
TM
power supply series safety approval applies to the following operating conditions:
*Indoor use
*Ambient temperature: 0°C to 50°C
*Maximum relative humidity: 90% (no condensation)
*Altitude: up to 3000m
*Pollution degree 2
ATTENTION Observe Precautions for handling Electrostatic Sensitive Devices.
CAUTION Risk of Electrical Shock
Instruction manual symbol. The instrument will be marked with this symbol when it is
necessary for the user to refer to the instruction manual.
Indicates hazardous voltage.
Indicates ground terminal.
Protective Ground Conductor Terminal must be connected to Earth Ground.
Off (Supply)
On (Supply)
The WARNING sign denotes a hazard. An attention to a procedure is called.
Not following procedure correctly could result in personal injury.
A WARNING sign should not be skipped and all indicated conditions must be
fully understood and met.
The CAUTION sign denotes a hazard. An attention to a procedure is called. Not
following procedure correctly could result in damage to the equipment. Do not proceed
beyond a CAUTION sign until all indicated conditions are fully understood and met.