3.4 Rack Mounting
The Genesys
™ power supply series is designed to fit in a standard 19” equipment rack.
3.4.1 To install the Power Supply in a Rack:
Use the front panel rack-mount brackets to install the power supply in the rack. Use a
support bar to provide adequate support for the rear of the power supply. Do not
obstruct the air exhaust at the rear panel of the unit.
3.4.2 Rack Mount Slides (optional):
CAUTION
Ensure that the screws used to attach the slides to the unit do not
penetrate more than 6mm into the sides of the unit.
Use rack mount slides: General Devices P/N: C-300-S-116 or equivalent to install the
unit in a
standard 19” equipment rack. Refer to Fig. 3-1 for slides assembly instructions.
Use three #10-
320x0.38” (max.) screws at each side. To prevent internal damage, use
the specified screw length only.
Fig. 3-1: Rack-Mount Slides Assembly
3.5 Location, Mounting and Cooling
This power supply is fan cooled. The air intake is at the front panel and the exhaust is at the
rear panel. Upon installation, allow cooling air to reach the front panel ventilation inlets.
Allow a minimum of 10cm (4 Inch) of unrestricted air space at the front and the rear of the
unit.
The power supply should be used in an area that the ambient temperature does not exceed
+50°C.
3.6 AC Source Requirements
The Genesys
TM
series can be operated from a nominal 100V to 240V, single phase, 47
63
Hz. The input voltage range and current required for each model is specified in Chapter 2.
Ensure that under heavy load, the AC voltage supplied to the power supply does not fall
below the specifications described in Chapter 2.