83-530-000 Rev G
10
CHAPTER 2 SPECIFICATIONS
All specifications are subject to change without notice.
Contact factory for specific model availability.
1.1 STANDARD MODELS - 10kW
1.Rated output voltage
V
7.5
10
12.5
20
25
30
40
50
60
80
100
125
150
200
250
300
400
500
600
2.Rated Output Current
A
1000
1000
800
500
400
333
250
200
167
125
100
80
66
50
40
33
25
20
17
3.Rated output power
kW
7.5
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
9.9
10.0
10.0
9.9
10.0
10.0
10.2
1.1 STANDARD MODELS - 15kW
1.Rated output voltage
V
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
60
80
100
125
150
200
250
300
400
500
600
2.Rated Output Current
A
250
187.5
150
120
100
75
60
50
37.5
30
25
3.Rated output power
kW
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
2.INPUT CHARACTERISTICS
V
7.5
10
12.5
20
25
30
40
50
60
80
100
125
150
200
250
300
400
500
600
1. Input voltage/freq.(range)
---
2.No of phase
---
3 Phase (Wye or Delta) 4 wire total (3 Phase and 1 protective earth ground)
3. Dropout voltage
V
4. Input current 180/360/432Vac
A
10kw - 45/23/20
15kW - 64/32/27
All at full rated output power.
5. Power Factor
---
6. Efficiency at Low Line,100% load
%
7. Inrush current
A
8. Leakage current
mA
9. Input Protection
---
10. Fuse
---
400/480 Input Only
11. Input Overvoltage Protection
12. Phase Imbalance
%
3. STATIC CHARACTERISTICS
V
7.5
10
12.5
20
25
30
40
50
60
80
100
125
150
200
250
300
400
500
600
1. Max. line regulation c.v
---
2. Max. line regulation c.c
---
3. Max load regulation c.v
---
4. Max load regulation c.c
---
5. Temp. drift c.v
---
+/-0.05% of Full Scale Over 8 hours, after 30 minute warm up, constant Line, Load & Temperature
6. Temp. drift c.c
---
+/-0.05% of Full Scale Over 8 hours, after 30 minute warm up, constant Line, Load & Temperature
7. Stability c.v
PPM/C
200 (0.02% Full Scale)/Degree C
8. Stability c.c
PPM/C
300( 0.03% Full Scale)/ Degree C
9. Output noise p-p(20MHz) c.v
mV
60
60
60
60
60
60
60
75
75
100
100
125
135
135
200
200
200
300
350
10. Ripple r.m.s 5Hz~1MHz c.v
mV
20
20
20
20
20
20
20
20
20
25
25
25
25
35
35
60
60
60
60
11. Ripple r.m.s 5Hz~1MHz c.c (10kW)
mA
5100
5100
2600
2600
1700
1700
100
80
67
50
40
32
20
20
16
13
10
8
7
12. Ripple r.m.s. 5Hz~1MHz c.c (15kW)
mA
–
–
–
–
–
–
–
–
100
100
100
50
50
20
20
20
10
10
10
13. Rem. sense compensation/wire
V
1
1
1
1
1
1.5
2
3
3
4
5
5
5
5
5
5
5
5
5
4.PROTECTIVE FUNCTIONS
V
7.5
10
12.5
20
25
30
40
50
60
80
100
125
150
200
250
300
400
500
600
1. OCP
%
0~100
2. OCP type
---
Constant current
3. Knee point protection
---
None. No damage at knee point operation
4. Short circuit protection
---
Yes
5. Short circuit burn-in
---
Yes
6. Foldback protection
---
7. Foldback response time
S
Less than 1
8. OVP type
---
9. OVP programming accuracy
%
5% Full Scale
10. OVP adjustment method
---
11. OVP trip point
V
12. OVP response time
mS
13. Max. OVP reset time
S
14. Output under voltage limit
---
Preset by front panel or communication port. Prevents from adjusting Vout below limit.
Raises the Output good signal in case of output voltage is below limit.
15. Input under voltage protection
---
Yes. Power supply shut down below low line.
16. Over temp. protection
---
17. Phase Loss Protection
208VAC (180-253); 400VAC (360-440); 480VAC (432-528), all 47-63Hz.
175/355/425
0.1% of FS from Io min. to Io max
0.01% of FS from lo min. to lo max
0.05% of FS from lo min. to lo max
Unit shall not be damaged by line overvoltage with max. duration of 100uSec. Up to 120% of nominal AC input voltage.
0.88 Passive
Less than 10mS for Output to begin to drop.
0.1% of FS from Io min. to Io max
0.1% of FS from Vo min. to Vo max
0.1% of FS from Vo min. to Vo max
0.02% of FS lo min. to lo max
0.75% of FS from Vo min. to Vo max
77min for 7.5KW, 83 min for 10kW; 88 min for 15kW
Not to exceed full rated Input current See Para. 2.4
*Ripple and Noise at Full Rated Voltage & Load at 25C, Nominal Line. For models not listed use the ripple limit of the next higher voltage model. Per EIJ RC9002A
3.5 (EN60950-1) max.
208 Circuit Breaker, 400/480 - Line Fuse
7 from Turn On.
Yes
1. OUTPUT RATING (Duty Cycle Continuous Duty).
Inverter shut-down, manual reset by On/Off recycle or by OUT button
Adjust by front panel Voltage encoder and comm port.
0.05 to (1.02-1.05) x Rated Output Voltage
Unit shall shut down when internal temperature exceeds safe operating levels. (Latched in Safe mode and
unlatched in auto mode).
= < 5% on Three Phase Input
Output shut down , manual reset by front panel OUT button.