8.3 ISOLATED PROGRAMMING & MONITORING CONNECTOR
Refer to Table 8-1 for detailed description of the rear panel Isolated Programming & Monitoring
connector. To provide the lowest noise performance, it is recommended to use shielded-twisted pair
wiring.
Refer to Fig.8-1 for description of the connector.
Isolated programming plug P/N: MC1.5/8-ST-3.81, Phoenix.
Table 8-1: Detailed description of Isolated programming & Monitoring connector
Terminal
Signal name
Function
Range 0-5/0-
10V
IS510 option
Range 4-20mA
IS420 option
1
SHLD
Shield, connected internally to
chassis of the supply.
Chassis ground
2
+VPROG_ISO
Output voltage programming in-
put
0-5/0-10V
4-20mA
3
+IPROG_ISO
Output current programming in-
put
0-5/0-10V
4-20mA
4
GND_ISO
Ground for programming signals.
Ground
Ground
5
GND_ISO
Ground for programming signals.
Ground
Ground
6
+VMON_ISO
Output voltage monitoring output
0-5/0-10V
4-20mA
7
+IMON_ISO
Output current monitoring output
0-5/0-10V
4-20mA
8
SHLD
Shield, connected internally to
chassis of the supply.
Chassis ground
1
2
3
4
5
6
7
8
Shield
+VPROG_ISO
+IPROG_ISO
GND_ISO
Shield
+IMON_ISO
+VMON_ISO
GND_ISO
Fig.8-1: Isolated Programming & Monitoring connector