- 19 -
TDK-Lambda
EZA2500 series
Quick Manual / Basic
①
②
③
④
⑤
5) Confirm EZA startup
You can check that EZA is running as follows.
● The cooling fan rotates.
● The green "GEN" or "REG" LED on the front panel turns on.
● Check the EZA status via RS485.
The confirmation using “CNVCommCC” via RS485 is explained below.
①
Click the “Main” tag in a state where it can communicate with EZA.
②
"[02] Converter Status" Click the “READ” in Converter Status.
③
"Charging" is displayed in the square under "Running State".
④
Click the "READ" in "[10] Converter Meter1.
⑤
Battery voltage value etc. at the time of clicking the "READ", will be displayed in
the square beside it.
EZA will rotate the cooling fan for about 3 minutes to cool the interior
even after the main converter stops, then stop the fan.