HWS/ME
HWS/HD
Line up
P31
Line up
P51
●
Immunity (All models)
Attention:
Please read the instruction manual carefully before using this product. On top of the following condition, please refer to to "HWS Series" standard instruction manual (p25-).
Please confirm whether there is insulation materials used inside the equipment (whether there is patient direct contact or indirect contact with the equipment). All models are
approved for basic insulation, therefore additional insulation circuit may be needed in the equipment.
●
Emission (HWS30,50,100,150,300/ME)
●
Emission (HWS 600,1500/ME)
Medical safety standard (EN60601/UL60601)
compliance
7 models with 42 line ups
Contribute to shortened the time needed in develop-
ing medical equipment and reduce its cost
Designed to meet MIL-STD-810F
(shock and vibration)
PCB coating
-40
℃
Start up
Era where standard power supply used in medical application
Harsh environment applications
AC/DC Standard switching power supply
for rugged and heavy duty
Items
Electrostatic
Radiated susceptibility
Electrical fast transient/burst
Surge
Conducted susceptibility
Power frequency magnetic field
Voltage dips. Short interuption
Standard
lEC61000-4-2
lEC61000-4-3
lEC61000-4-4
lEC61000-4-5
lEC61000-4-6
lEC61000-4-8
lEC61000-4-11
Compliance Level
Level3
(Level 2,3 for
300W, 600W)
Level 3
Level 3
Level 3,4
Level 3
Level 4
Complied
Notes
Aerial discharge: 8kV
Contact discharge:6kV
(4kV for 1500W)
10V/m
2kV
Common: 4.0kV
Differential mode: 2.0kV
10V
30A/m
Test items
Radiated electric field
Conducted emissions
Conducted harmonics
Flicker
Standard
EN55022/EN55011,FCC,VCCI
EN55022/EN55011,FCC,VCCI
IEC61000-3-2
IEC61000-3-3
Notes
Class B Compliance
Class B Compliance
Conformed
Conformed
Test items
Radiated electric field
Conducted emissions
Conducted harmonics
Flicker
Standard
EN55022/EN55011,FCC,VCCI
EN55022/EN55011,FCC,VCCI
IEC61000-3-2
IEC61000-3-3
Notes
Class A Compliance
Class A Compliance
Conformed
Conformed
Medical lasers,
X-Ray,
Microwave thera-
phy equipment
Diagnosis equip-
ments,
Analysis/testing
devices
Main applications
Leakage current: max. 0.5mA
100VAC(Typ): 0.2mA/30〜150W、0.15mA/300W、0.12mA/600W、 0.2mA/1000〜1500W
230VAC(Typ): 0.4mA/30〜150W、0.39mA/300W、0.34mA/600W、 0.4mA/1000〜1500W
EMC
HWS
Series
AC/DC Switching power supply for
medical application
Main applications
LED display
Device
Process
control
Factory
machinery