【HWS100/HD】
MOUNTING A
(STANDARD MOUNTING)
MOUNTING B
MOUNTING C MOUNTING D
DON T USE
Ta(℃)
LOAD(%)
−10 to +40
50
60
71
100
100
60
20
100
80
60
20
*COOLING : CONVECTION COOLING
MOUNTING A
MOUNTING B, C, D
120
100
80
60
40
20
0
0
10
20
30
40
50
60
7071
80
-10
MOUNTING A
MOUNTING B,C,D
Ta(℃)
LOAD(%)
80
100
120
60
40
20
0
85
170
265
Normal start up.
Stable output after
1 min from start up.
Input Voltage
(VAC)
LOAD
(%)
DERATING CURVE
=NOTES=
*At Ta : -30 to -10
℃
.
*Output voltage : Nominal output voltage.
*Input voltage : Not gradual start up.
*Do not use the load that is constant current mode.
*Avoid forced air cooling. It is assumed that inside of power supply is heated
by self-heating within 1 minutes.
*No dewdrop.
*Output voltage might be unstable at no load. In that case, apply minimum
output current.
*Pay attention to above items before using the unit. Incorrect usage could
lead to unstable output voltage.
Input Voltage
(VAC)
Normal start up.
LOAD
(%)
Stable output after 1 min
from start up.
85
170
70
100
100
100
80
70
60
50
40
30
20
10
0
90
170
265
Input Voltage
(VAC)
LOAD
(%)
Normal start up.
Stable output after
3 min from start up.
DERATING CURVE
=NOTES=
*At Ta : -40 to -10
℃
.
*Output voltage : Nominal output voltage.
*Input voltage : Not operate at 85 - 90VAC, and not gradual start up.
*Do not use the load that is constant current mode.
*Avoid forced air cooling. It is assumed that inside of power supply is heated
by self-heating within 3 minutes.
*No dewdrop.
*Output voltage might be unstable at no load. In that case, apply minimum
output current.
*Pay attention to above items before using the unit. Incorrect usage could
lead to unstable output voltage.
90
170
30
50
60
70
Input Voltage
(VAC)
Normal start up.
LOAD
(%)
Stable output after 3 min
from start up.
●DERATING TO START UP AT Ta : -30 to -10℃
●DERATING TO START UP AT Ta : -40 to -10℃
(10.1)
VOLTAGE ADJUSTMENT
(14)
28±1
(9)
8.4
10
9.2
8.6
7.3
2-M4
5-M3.5
19MAX
135±0.5
(17)
160±1
8
8
68
±
0
.5
(75)
LED
M4
M4
8
2±1
2-M3 TAPPED HOLES
SCREW PENETRATION DEPTH MAX. 6mm
AC(N)
FG
AC(L)
-S
-V
+V
+S
N
L
FG
−S
−V
+S
+V
(5.5)
17
15.5
(15)
125±0.5
NAME PLATE
20
2-M3 EMBOSSED, TAPPED AND COUNTERSUNK HOLES
SCREW PENETRATION DEPTH MAX. 6mm
[unit:mm]
Terminal
Recommended Solderless Terminal
D
(max)
t
(max)
Qty
(max)
+V / −V
8.1mm
0.8mm
2pcs
1.0mm
1pc
Others
6.8mm
0.8mm
2pcs
D
t
ACCESSORIES
* SHORT PIECE (NET 2) FOR SHORT-
ING PURPOSE (+S to +V, -S to -V) :
MOUNTED AT TIME OF SHIPMENT.
OUTPUT DERATING CURVE
HWS
100/HD
Output Derating
Start-up condition at low temperature
Outline Drawing
37
・All specifications are subject to change without notice.