108
・All specifications are subject to change without notice.
Instruction Manual
HWS
HWS HD
HWS ME
HWS-P
HWS
1500
Please be aware that if CNT terminal and TOG terminal
is short and input voltage is gradually increase, this will
trigger the low output voltage detector protection circuit
and will result to output voltage shut down.
When the low output voltage detector protection circuit is
triggered, the input power is cut off for a few minutes, and
then power is re-input or remote ON/OFF control signal
should be input for recovery of the output.
Output Ripple & Noise
Maximum ripple & noise value in specifi cations is measured
according to measurement circuit specified by JEITA-
RC9131A. When Load lines are longer, ripple & noise
becomes larger. In this case, electrolytic capacitor, film
capacitor, etc. might be necessary to use across the load
terminal. The output ripple & noise cannot be measured
accurately if the probe ground lead of oscilloscope is too long.
Series Operation
For series operation, either method (A) or (B) is possible.
There might be a step in the rise waveform during series
operation.
Power
supply
Load
Method(B)
Method(A)
(Note1)
Load
+
-
Power
supply
+
-
Power
supply
+
-
+
-
Load
+
-
Power
supply
+
-
(Note1)
Please connect a diode for by-pass when using method (A)
of the series operation.
Please use the diode with rated forward current is equal or
more than load current and that the rated maximum reverse
voltage is higher than output voltage for each power supply.
Parallel Operation
Current balancing function is provided. Either of operations
mode (A) or (B) is possible.
(A)To Increase the Output Current
Current balancing function activates by connecting
PC-to-PC terminal and COM-to-COM terminal, and
output current of each power supply is equivalently
supplied to load. Wires to PC terminals shall be as
short as possible, same length and twisted.
There is a possibility that output could be unstable
caused by external noise. For this case, disconnect
COM terminal and connect -S terminal from parallel
power supply to a single point on the load. Please re-
fer connection Method (A)-2.
1) Adjust the output voltage of each power supply to be
same value within 1% or 100mV, whichever is smaller.
2)
Use same length and type of wires for all load lines.
3)
Maximum value of output current in parallel is up to
80% of all paralleled models.The purpose of the current
balancing function is the static power-up. Therefore
the output voltage might decrease according to the
condition of dynamic load. There might be a step in the
rise waveform during parallel operation.
4) Up to 5 units can be connected in parallel.
(B)To Use as a Backup Power Supply
1) Set power supply output voltage higher by the for-
ward voltage drop of diode.
2) Adjust the output voltage of each power supply to
be same value.
3) Use within the specifications for output voltage
and output power.
(C)In the case of parallel connections, it is possible to
control the output voltage by adjusting the volume
from only 1 unit. Choose 1 unit that would act as the
master and this unit's volume will determine the out-
put voltage. The volume on each slave units must be
turned clockwise to maximum position. Then adjust
the master volume to set the output voltage.
Connection for this application is shown in fi gure (c).
Load
Load
Method
(A)
-1
Power
Supply
COM
PC
COM
PC
+
-
Power
Supply
+
-
Method
(A)
-2
Power
Supply
+
+S
-
-S
+S
-S
+S
-S
Power
Supply
+
+S
-
-S
COM
PC
COM
PC
Isolation Test
Isolation resistance between output and FG (chassis) shall
be more than 100MΩ at 500VDC and between output and
CNT・PF shall be more than 10MΩ at 100VDC. For safety
operation, voltage setting of DC isolation tester must be
done before the test. Ensure that it is fully discharged after
the test.
+
S
+
-
-
S
PC
CNT
TOG
PF
FG
AC
(L)
AC
(N)
Isolation tester
+
S
+
-
-
S
PC
CNT
TOG
PF
FG
AC
(L)
AC
(N)
Isolation tester
Output − FG (chassis)
500VDC 100MΩ or more
Output − CNT・PF
100VDC 10MΩ or more
Load
Load
Method
(B)
Output Power(W)=(Vo+Vf)×Io
Power
Supply
+
-
Power
Supply
+
-
-S
+S
-S
+S
Vf Io
→
Vo+Vf
Vo
Vo+Vf
Vf
Method
(C)
Power
Supply
REF PV COM PC
REF PV COM PC
+
-
+
-
+
-
+S
+
+
-S
-
Load
Co-axial cable
1.5m 50Ω
Oscillo-
Scope
R:50Ω
C1:4700pF
C2:100μF
C3:0.47μF
R
C1
C2
C3
Bandwidth
100MHz
Power Supply Unit