Set air volume and duration for the supply air blast
in its duration (long hose = long air blast),
adjusted in its volume (heavy screw = larger volume).
The supply air shock is set correctly when the screws reach the mouthpiece
without interference, but are not shot out of the mouthpiece.
To set the duration of the supply air blast, please follow the instructions in
chapter 9.9.2 Supply air blast.
To adjust the air volume of the supply air blast, turn the throttle screw (see
Fig15)
-clockwise to reduce the air volume,
-counterclockwise to increase the air volume.