background image

 

02/2014 

TCS TürControlSysteme AG, TCS Hotline Germany: [email protected]

 

Subject to technical changes. 

www.tcsag.de

 

PI_FBI610x_uk   3 A 

 

Commissioning 

  Install the devices of the system completely. 

  Check the a-, b- and P-wire against each other for short-circuits. 

  Switch on the mains voltage. 

After switching on the voltage supply, the FBI610x starts automatically.  

 

Note 

!

 

The SIP Gateway restarts automatically after a voltage interruption, even if the 
device was switched off. 

!

 

Switching off the power supply during a storage process or software update can cause 
a loss of data or a malfunction of the device. 

 

Error detection and indication 

Error at the TCS:BUS 

Only operation mode PASSIVE:

 a-wire is not 

connected / not supplied, a-b short-circuit or a- 
and P-wire are interchanged / short-circuited 

Only operation mode ACTIVE

: a-b or a-P 

short-circuited 

                       ERR 

 
 
 

error indication flashes 

(1:7, 1 Hz)

 

 
Connect a-wire / check power 
supply, 
interchange a- and P-wire or re-
move short-circuit,  
device is in standby mode again 
 

Network error 
defective network connection or no connection 
to the SIP server 
 

                       ERR 

 
 

 

error indication  

flashes out 

(7:1, 1 Hz)

 

Check the network, check data 
transmission, check login data for 
SIP server, 

 

device is in standby mode again 

Network error 
defective network connection or no connection 
to the SIP server 
 

 
 
 

                      4 

error indication SIP 

lights up *

 

Check the network, check the 
data transmission, check the 
SIP server, 
device is in standby mode again 

 

*

 No error during the start process, indication, lights up and expires after around. 40 sec if no error was detected. 

 

Start browser: connection establishment PC 

– SIP Gateway 

Prepare the intranet connection 

The PC/Laptop must be equipped with a network connection and the device must be lo-
cated in the same subnet as the SIP-Gateway. If your network and server are working in 
the 192.168.1 address area (C net), you can directly access the SIP-Gateway (provided 
that another device does not use the IP address of the SIP-Gateway). 
Otherwise the used PC/Laptop must be set temporary to an IP address within the address 
area of the FBI610x to establish a connection with the SIP-Gateway. To install / modify 
your network connection, please use the network installation assistant or the help menu of 
your operating system (catchword: 

Install the network

). If several FBI610x, which are in 

delivery state, are to be installed within one network, the devices must be commissioned 
one by one and assigned to a free IP address. 
 
 
 
 

Содержание FBI6100-0400

Страница 1: ...ysteme AG TCS Hotline Germany hotline tcsag de Subject to technical changes www tcsag de PI_FBI610x_uk 3 A Product information SIP Gateway for 115 call destinations FBI6100 0400 for 10 call destinatio...

Страница 2: ...repare the intranet connection 8 Example network setup under Windows XP 9 Establish a network connection for configuration 10 Enter change IP address 11 Change the password 11 Enter change SIP setting...

Страница 3: ...lines within shared cable ducts use of standard communication lines e g J Y St Y with 0 8 mm diameter existing lines modernisation with deviating cross sections can be used in compliance with the loop...

Страница 4: ...tch unit max permitted contact load capacity of 24 V DC 1 A staircase light control unit FNA1000 or TZ1 SG with 8 24 V AC relay adjustable light switch time 0 to 99 sec adjustable function via web int...

Страница 5: ...0 output voltage idle state U a b 24 V 1 V U b P 26V 1V output voltage speaking U a b 22 V 1 V output current I a 40 mA max output current I Pmax 180 mA operation mode PASSIVE supply voltage 26 V 8 po...

Страница 6: ...VE or ACTIVE potential free relay contacts closing contacts to control automatic light switch units door opener single speech channel Communication from front door and indoor stations to more than one...

Страница 7: ...2014 7 TCS T rControlSysteme AG TCS Hotline Germany hotline tcsag de Subject to technical changes www tcsag de PI_FBI610x_uk 3 A Wiring example operation mode ACTIVE Wiring example operation mode PASS...

Страница 8: ...eck the network check data transmission check login data for SIP server device is in standby mode again Network error defective network connection or no connection to the SIP server 4 error indication...

Страница 9: ...ord Network setup Example network setup under Windows XP Open the Network and data telecommunication connections in one of the following methods 1 Click with the right mouse button on the icon Network...

Страница 10: ...ablish a connection from the PC Laptop to the SIP Gateway via switch or router Alternatively connect the SIP Gateway directly to a PC Laptop via a crossover cable twisted pair cable Open an internet b...

Страница 11: ...Confirm with Save If the IP address was changed manually the web browser can possibly no longer dis play the page with the feedback If this is the case enter the new IP manually into the browser to g...

Страница 12: ...e IP address or URL of the SIP providers SIP server The port number shows to which port the server belongs SIP domain The SIP domain is used to identify devices and to establish a connection Thus the...

Страница 13: ...l characters serial number TCS BUS serial number which is to be programmed at the front door station The serial num ber has max 6 digits Shorter serial numbers are entered and displayed without leadin...

Страница 14: ...n the programming mode of the system In the operation mode ACTIVE Shortly press the RUN PROG button at the FBI610x or in the operation mode PASSIVE Shortly press the RUN PROG button at your power supp...

Страница 15: ...ton 7 must be pressed to accept the call The controlling of the FBI610x is realised via the MFV dial of the connected telephone Call from a telephone to a front door station A telephone can establish...

Страница 16: ...tory setting yellow LED lights up yellow LED blinks yellow LED blinks fast yellow LED lights up Press RUN PROG button and hold it keep RUN PROG button pressed until LED blinks then release factory set...

Отзывы: