8
02/2014
TCS TürControlSysteme AG, TCS Hotline Germany: [email protected]
Subject to technical changes.
www.tcsag.de
PI_FBI610x_uk 3 A
Commissioning
Install the devices of the system completely.
Check the a-, b- and P-wire against each other for short-circuits.
Switch on the mains voltage.
After switching on the voltage supply, the FBI610x starts automatically.
Note
!
The SIP Gateway restarts automatically after a voltage interruption, even if the
device was switched off.
!
Switching off the power supply during a storage process or software update can cause
a loss of data or a malfunction of the device.
Error detection and indication
Error at the TCS:BUS
Only operation mode PASSIVE:
a-wire is not
connected / not supplied, a-b short-circuit or a-
and P-wire are interchanged / short-circuited
Only operation mode ACTIVE
: a-b or a-P
short-circuited
ERR
error indication flashes
(1:7, 1 Hz)
Connect a-wire / check power
supply,
interchange a- and P-wire or re-
move short-circuit,
device is in standby mode again
Network error
defective network connection or no connection
to the SIP server
ERR
error indication
flashes out
(7:1, 1 Hz)
Check the network, check data
transmission, check login data for
SIP server,
device is in standby mode again
Network error
defective network connection or no connection
to the SIP server
4
error indication SIP
lights up *
Check the network, check the
data transmission, check the
SIP server,
device is in standby mode again
*
No error during the start process, indication, lights up and expires after around. 40 sec if no error was detected.
Start browser: connection establishment PC
– SIP Gateway
Prepare the intranet connection
The PC/Laptop must be equipped with a network connection and the device must be lo-
cated in the same subnet as the SIP-Gateway. If your network and server are working in
the 192.168.1 address area (C net), you can directly access the SIP-Gateway (provided
that another device does not use the IP address of the SIP-Gateway).
Otherwise the used PC/Laptop must be set temporary to an IP address within the address
area of the FBI610x to establish a connection with the SIP-Gateway. To install / modify
your network connection, please use the network installation assistant or the help menu of
your operating system (catchword:
Install the network
). If several FBI610x, which are in
delivery state, are to be installed within one network, the devices must be commissioned
one by one and assigned to a free IP address.