Safety instructions
!
Attention! Mounting, installation, commissioning and repair of electronic devices have
to be carried out only by qualified electricians. Thus, the current standards for the in-
stallation of door communication systems must be observed!
For working with main connection of 230 V alternating voltage, the safety regulations ac-
cording to DIN VDE 0100 must be observed.
When installing TCS:BUS systems, the general safety regulations for telecommunication
systems according to VDE 0800 must be observed. Inter alia:
separated conduit of heavy and low current lines,
minimum distance of 10 cm in case of a common cable conduit,
use of separators between heavy and low current lines within shared cable ducts,
use of standard communication lines, e.g. J-Y (St) Y with 0.8 mm diameter,
existing lines (modernisation) with deviating cross-sections can be used in compliance
with the loop resistance.
!
With suitable measures to protect against lightning, it has to be ensured that a voltage
of each 32 V DC is not exceeded at the a- and b-wire.
Connections, indication and operating elements
Labelling
Function
19|20
connection for supply
voltage
Only operation mode ACTIVE!
8 - 12 V AC (from bell
transformer NWV1000-0400)
23|24|25
a*/b*/P*
connection TCS:BUS
ACTIVE
Only operation mode ACTIVE
!
The SIP-Gateway realises the supply voltage for a
BUS strand.
In this operation mode, a front-door station can be
connected to the network at minimal effort.
One audio front-door station (incl. extensions) and 3
audio indoor stations can be operated in this mode.
The selection of connectable devices must be real-
ised in compliance with the max. quiescent current
output of the FBI610x.
Terminals are short-circuit protected.