PI_FBI610x_uk   3 A 

 

Safety instructions 

 

!

 

Attention! Mounting, installation, commissioning and repair of electronic devices have 
to be carried out only by qualified electricians. Thus, the current standards for the in-
stallation of door communication systems must be observed! 

 
For working with main connection of 230 V alternating voltage, the safety regulations ac-
cording to DIN VDE 0100 must be observed. 
 
When  installing  TCS:BUS  systems,  the  general  safety  regulations  for  telecommunication 
systems according to VDE 0800 must be observed. Inter alia: 
 

  separated conduit of heavy and low current lines, 

  minimum distance of 10 cm in case of a common cable conduit, 

  use of separators between heavy and low current lines within shared cable ducts, 

  use of standard communication lines, e.g. J-Y (St) Y with 0.8 mm diameter, 

  existing lines (modernisation) with deviating cross-sections can be used in compliance 

with the loop resistance. 
 

!

 

With suitable measures to protect against lightning, it has to be ensured that a voltage 
of each 32 V DC is not exceeded at the a- and b-wire. 

 
 
 

Connections, indication and operating elements 

 

 

Labelling 

Function 

 

19|20 

connection for supply 
voltage 

Only operation mode ACTIVE! 

8 - 12 V AC (from bell 

transformer NWV1000-0400) 

 

23|24|25 

a*/b*/P* 
connection TCS:BUS 
ACTIVE 

Only operation mode ACTIVE

!  

The SIP-Gateway realises the supply voltage for a 
BUS strand. 

  In this operation mode, a front-door station can be 

connected to the network at minimal effort. 

  One audio front-door station (incl. extensions) and 3 

audio indoor stations can be operated in this mode. 

  The selection of connectable devices must be real-

ised in compliance with the max. quiescent current 
output of the FBI610x. 

  Terminals are short-circuit protected. 

Содержание FBI6100-0400

Страница 1: ...ysteme AG TCS Hotline Germany hotline tcsag de Subject to technical changes www tcsag de PI_FBI610x_uk 3 A Product information SIP Gateway for 115 call destinations FBI6100 0400 for 10 call destinatio...

Страница 2: ...repare the intranet connection 8 Example network setup under Windows XP 9 Establish a network connection for configuration 10 Enter change IP address 11 Change the password 11 Enter change SIP setting...

Страница 3: ...lines within shared cable ducts use of standard communication lines e g J Y St Y with 0 8 mm diameter existing lines modernisation with deviating cross sections can be used in compliance with the loop...

Страница 4: ...tch unit max permitted contact load capacity of 24 V DC 1 A staircase light control unit FNA1000 or TZ1 SG with 8 24 V AC relay adjustable light switch time 0 to 99 sec adjustable function via web int...

Страница 5: ...0 output voltage idle state U a b 24 V 1 V U b P 26V 1V output voltage speaking U a b 22 V 1 V output current I a 40 mA max output current I Pmax 180 mA operation mode PASSIVE supply voltage 26 V 8 po...

Страница 6: ...VE or ACTIVE potential free relay contacts closing contacts to control automatic light switch units door opener single speech channel Communication from front door and indoor stations to more than one...

Страница 7: ...2014 7 TCS T rControlSysteme AG TCS Hotline Germany hotline tcsag de Subject to technical changes www tcsag de PI_FBI610x_uk 3 A Wiring example operation mode ACTIVE Wiring example operation mode PASS...

Страница 8: ...eck the network check data transmission check login data for SIP server device is in standby mode again Network error defective network connection or no connection to the SIP server 4 error indication...

Страница 9: ...ord Network setup Example network setup under Windows XP Open the Network and data telecommunication connections in one of the following methods 1 Click with the right mouse button on the icon Network...

Страница 10: ...ablish a connection from the PC Laptop to the SIP Gateway via switch or router Alternatively connect the SIP Gateway directly to a PC Laptop via a crossover cable twisted pair cable Open an internet b...

Страница 11: ...Confirm with Save If the IP address was changed manually the web browser can possibly no longer dis play the page with the feedback If this is the case enter the new IP manually into the browser to g...

Страница 12: ...e IP address or URL of the SIP providers SIP server The port number shows to which port the server belongs SIP domain The SIP domain is used to identify devices and to establish a connection Thus the...

Страница 13: ...l characters serial number TCS BUS serial number which is to be programmed at the front door station The serial num ber has max 6 digits Shorter serial numbers are entered and displayed without leadin...

Страница 14: ...n the programming mode of the system In the operation mode ACTIVE Shortly press the RUN PROG button at the FBI610x or in the operation mode PASSIVE Shortly press the RUN PROG button at your power supp...

Страница 15: ...ton 7 must be pressed to accept the call The controlling of the FBI610x is realised via the MFV dial of the connected telephone Call from a telephone to a front door station A telephone can establish...

Страница 16: ...tory setting yellow LED lights up yellow LED blinks yellow LED blinks fast yellow LED lights up Press RUN PROG button and hold it keep RUN PROG button pressed until LED blinks then release factory set...

Отзывы: