background image

 

02/2014 

TCS TürControlSysteme AG, TCS Hotline Germany: [email protected]

 

Subject to technical changes. 

www.tcsag.de

 

PI_FBI610x_uk   3 A 

 

Intended use 

 

  The FBI610x is an interface for the connection of TCS front-door stations to a VoIP net-

work as end device (client) via Session Initiation Protocol (SIP).  

  The SIP-Gateway can be used generally in 2 operation modes at the TCS:BUS: opera-

tion mode ACTIVE

 

or

 

operation mode PASSIVE

.

 

 
 
 

Short description 

 

  providing the voltage supply of 24 V DC (for TCS:BUS, only operation mode ACTIVE) 

  switching of the system mode between operation and programming mode,  

LED indication (only in operation mode ACTIVE). 

  automatic detection of the operation mode PASSIVE or ACTIVE 

  potential-free relay contacts (closing contacts) to control automatic light switch units / 

door opener  

  single speech channel: 

Communication from front-door and indoor stations to more than one call destination is 
not possible simultaneously. 

  optical indication for voice connection and operating voltage 

  error detection and indication for TCS:BUS and network errors 

 
 
 

Connect the lines 

Notes 

 

Mounting, installation and commissioning must be carried out only by IT professionals! 

 

!

 

Use a small screwdriver to connect the lines and to avoid damaging the device. 

 

Connect the TCS system 

  Strip the ends of the lines. 

  Connect the TCS system to the FBI610x depending on the operation mode and the type 

of system completely and according to the wiring example. 

 

Connect the network 

Establish a connection between the RJ45 interface at the FBI610x and your network by 
using a patch cord. 
 
 
 

Содержание FBI6100-0400

Страница 1: ...ysteme AG TCS Hotline Germany hotline tcsag de Subject to technical changes www tcsag de PI_FBI610x_uk 3 A Product information SIP Gateway for 115 call destinations FBI6100 0400 for 10 call destinatio...

Страница 2: ...repare the intranet connection 8 Example network setup under Windows XP 9 Establish a network connection for configuration 10 Enter change IP address 11 Change the password 11 Enter change SIP setting...

Страница 3: ...lines within shared cable ducts use of standard communication lines e g J Y St Y with 0 8 mm diameter existing lines modernisation with deviating cross sections can be used in compliance with the loop...

Страница 4: ...tch unit max permitted contact load capacity of 24 V DC 1 A staircase light control unit FNA1000 or TZ1 SG with 8 24 V AC relay adjustable light switch time 0 to 99 sec adjustable function via web int...

Страница 5: ...0 output voltage idle state U a b 24 V 1 V U b P 26V 1V output voltage speaking U a b 22 V 1 V output current I a 40 mA max output current I Pmax 180 mA operation mode PASSIVE supply voltage 26 V 8 po...

Страница 6: ...VE or ACTIVE potential free relay contacts closing contacts to control automatic light switch units door opener single speech channel Communication from front door and indoor stations to more than one...

Страница 7: ...2014 7 TCS T rControlSysteme AG TCS Hotline Germany hotline tcsag de Subject to technical changes www tcsag de PI_FBI610x_uk 3 A Wiring example operation mode ACTIVE Wiring example operation mode PASS...

Страница 8: ...eck the network check data transmission check login data for SIP server device is in standby mode again Network error defective network connection or no connection to the SIP server 4 error indication...

Страница 9: ...ord Network setup Example network setup under Windows XP Open the Network and data telecommunication connections in one of the following methods 1 Click with the right mouse button on the icon Network...

Страница 10: ...ablish a connection from the PC Laptop to the SIP Gateway via switch or router Alternatively connect the SIP Gateway directly to a PC Laptop via a crossover cable twisted pair cable Open an internet b...

Страница 11: ...Confirm with Save If the IP address was changed manually the web browser can possibly no longer dis play the page with the feedback If this is the case enter the new IP manually into the browser to g...

Страница 12: ...e IP address or URL of the SIP providers SIP server The port number shows to which port the server belongs SIP domain The SIP domain is used to identify devices and to establish a connection Thus the...

Страница 13: ...l characters serial number TCS BUS serial number which is to be programmed at the front door station The serial num ber has max 6 digits Shorter serial numbers are entered and displayed without leadin...

Страница 14: ...n the programming mode of the system In the operation mode ACTIVE Shortly press the RUN PROG button at the FBI610x or in the operation mode PASSIVE Shortly press the RUN PROG button at your power supp...

Страница 15: ...ton 7 must be pressed to accept the call The controlling of the FBI610x is realised via the MFV dial of the connected telephone Call from a telephone to a front door station A telephone can establish...

Страница 16: ...tory setting yellow LED lights up yellow LED blinks yellow LED blinks fast yellow LED lights up Press RUN PROG button and hold it keep RUN PROG button pressed until LED blinks then release factory set...

Отзывы: