Product description 

Intended use 

The video front door station series AVD/AVE with integrated code lock is suitable for surface-mount in the outdoor 
area. 
 

 

Modifications and repair of the device are only permitted, as far as described in this product information 
and executed by qualified electrician. Otherwise any claims under warranty and liability expire. 

 

 

Always observe the current legislation and labelling requirements during assembly and operation of 
video components. 

 

Short description 

Video front-door station 

 

Video front door stations with code lock for surface-mount with 1, 4, 6, 8, 10 or 12 bell buttons. 

 

Size of the nameplate: H 34 mm to 72 mm x W 74 mm (AVD), H 15 mm x W 39 mm (AVE) 

 

Colour: anodised natural (EN) 

 

colour camera CMOS sensor 380 TVL 

 

focal length f = 2.0 mm (F 2.5) 

 

light sensitivity 0 lux (IR on), 1 lux (IR off) 

 

diagonal detection angle 130° 

 

IR illumination for close-range illumination at night 

 

camera can be operated continuously 

 

metal housing made of robust aluminium profile 

 

bell button made of metal with maintenance-free contacts 

 

per bell button 2 indoor stations can be allocated 

 

durable and energy-saving LED name plate illumination 

 

shatter-proof name plate glass 

 

acknowledgement tone when pressing the bell button 

 

any bell bell button can be used to switch the light, light symbol enclosed 

 

conversation time ex works: 56 seconds / can be adjusted with Service Device and configo

TM

 

 

volume and microphone sensitivity can be adjusted manually 

 

pluggable memory to exchange front door stations that are identical in construction 

 

R-terminal to connect a functional extension: Door release 

 

door release time at R-terminal ex works: 3 seconds / can be adjusted with Service Device and configo

TM

 

 

Door call standby time ex works: 56 seconds / can be adjusted with Service Device and configo

TM

 

 

voice connection in door call standby time / can be adjusted with Service Device 

 

Code lock 

 

switching the light by pressing the #-button without code entry, can be deactivated 

 

0 codes, with a maximum of 8 digits for operation  

 

1 master code for maintenance and configuration, leading zeros are accepted 

 

code stop function to activate/lock a single code (only for memory loaction 1): Connecting a time switch (or motion 
detector, brightness sensor, door contact of a lock etc.) to a bipolar pluggable screw terminal is possible 

 

acoustic signalling when pressing the bell buttons, can be deactivated 

 

acoustic and optical signalling when the code is recognised 

 

acoustic and optical signalling when receiving a short door release protocol (if configured) 

 

button 5 with marking 

Содержание AVD Series

Страница 1: ...Product information Front door station series AVD AVE with integrated code lock...

Страница 2: ...nectingthelines 10 Connectthe floorpush button 10 Examplecircuit 11 Commissioningvideo 11 Extendedcodelock function 12 Initialoperation 12 Connectthe floorpush button 12 Settingthevolumeofmicrophonean...

Страница 3: ...lease in basic mode 21 Switching the lightinbasicmode 21 Repair 21 Exchanging the EEPROMstorage 21 FAQ 22 Errorindication detection 22 Cleaning 22 Conformity 22 Informationondisposal 23 Warranty 23 Se...

Страница 4: ...ilable for download at www tcsag de Usedsymbolsandwarningnotices Symbol signal word Explanation DANGER The signal word describes an endangering with a high level of risk Failure to observe this warnin...

Страница 5: ...communication lines e g J Y St Y with 0 8 mm diameter already existing lines modernisation with deviating cross sections can be used in compliance with the loop resistance requirementstoprotectagainst...

Страница 6: ...glass acknowledgement tone when pressing the bell button any bell bell button can be used to switch the light light symbol enclosed conversation time ex works 56 seconds can be adjusted with Service D...

Страница 7: ...onnectionterminal 13 connection forService Device bellbuttonextension 5 two colouredLED 14 nameplate illumination 6 Code lock keypad 15 volume controlmicrophone 7 bipolarpluggable screw terminal 16 vo...

Страница 8: ...o 0 button light switchinginbasic mode inputconfirmation in program ming mode button entryofcommandsequences andabortofincomplete com mand sequences in programming mode Technicaldata supply voltage 24...

Страница 9: ...vice damage The front door station must never be sealed using silicon Condensed water must be able to escape and evaporate Openingandclosingthehousing The lower aperture is connected to the aluminium...

Страница 10: ...losed in the delivery to connect lines Avoid damaging the device CAUTION Device damage The inner resistance of the door opener must not fall below 6 Ohm Strip the cable ends Connect the wires accordin...

Страница 11: ...ices of the system completely Then switch on the mains voltage Install the devices of the system completely Do not connect V1 and V2 with the P a or b wire Observe the polarity when connecting the vid...

Страница 12: ...is entered correctly and the contact according to the configuration of the switching input is effective Initial operation WARNING Danger to life due to electric shock Observe the safety regulations a...

Страница 13: ...oil Cut the name plates to the right size Push the name plate into the gab in the name plate glass from aside ill 11 Print the name plates on the special foil You can order the foil directly at TCS Wr...

Страница 14: ...dooropeneronlyduringanestablishedvoiceconnectionon off x setting the doorcallstandby time x setting the limitforthe conversation time x x setting thecalltime x setting the door release time x selectin...

Страница 15: ...he mains voltage The operating LED at the power supply and control unit is on Check if no programming lock is set Before you can reprogram an already programmed bell button you have to delete the prog...

Страница 16: ...programming mode Shortlypress theRUN PROGbutton The LED ison The programmingmodeofthesystem is switchedOFF 1 IftheresoundsaProgsperrtoneinstead atthefront doorstationaprogramminglockisset Youcandeact...

Страница 17: ...tone soundsand a ringtonesounds atthe front doorandindoorstation 1 Release thebell button 2b alternatively Programming via floor push button if the indoorstationis inaccessible Shortlypress the floor...

Страница 18: ...llbutton until the deletion tonesequence sounds Release thebellbutton 4 End programming mode Shortlypress theRUN PROGbutton The LED ison The programmingmodeofthesystem is switched OFF Programming the...

Страница 19: ...timesincorrectly Afterwards the codeinputislockedfor2min Thenstartagain Ifno command isenteredwithin the next2minutes the deviceauto matically quitsthe programming mode The LEDexpires Programming 2a...

Страница 20: ...ximumof8digits The programming lock cannot bedeactivatedmanually butonly withconfigoTM Determine the extended code lock function Input 12 function type Function type 0 externalcontacthas noinfluence 1...

Страница 21: ...ds the code inputis lockedfor2min Thenstartagain Switchingthelightinbasicmode 1 button to confirm button toconfirmwithoutenteringacode before Aspreconditionthefunctionmusthavebeenactivated programming...

Страница 22: ...xchange a andP wireorcorrect short circuit LEDexpires a wire isnotconnectedornot supplied Connectthe a wireorestablish power supply LEDexpires The buttonclamps press longer than 15sec release thebutto...

Страница 23: ...point Dispose the parts of the packaging in collecting tanks for cardboard and paper resp plastics Warranty We offer a simplified processing in case of warranty for qualified electricians Please conta...

Страница 24: ...wister Scholl Str 7 39307Genthin Germany FON 49 0 3933 8799 10 FAX 49 0 3933 879911 www tcsag de Subjecttotechnicalchanges TCS Hotline Germany FON 494194 9881188 Fax 494194 988129 Mail hotline tcsag d...

Отзывы: