Repeat the programming of an already programmed bell button, always change only the second serial 
number. If you want to change the serial number that was programmed first, you have to delete both 
serial numbers and then reprogram both serial numbers. 

 
 

Switching on the programming mode  

power supply and control unit 

 

 

  

Shortly press the RUN/PROG button. 

The LED blinks.   

The programming mode of the system is switched ON. 

2a  Programming via voice communication 

      or 

 

 

     

 

 

Establish a voice communication 
to the front-door station. 

Press the bell button until after 6 s a 
Prog2 sounds, keep the button pressed 
and after another 6 s a NoProg-tone 
sounds and ... 

…a ring tone sounds at the front 
door and indoor station.

1)

 

Release the bell 
button. 

2b  alternatively: Programming via floor push button (if the indoor station is inaccessible) 

 

 

 

  

 

 

Shortly press the floor push-button 
twice in quick succession. Each a 
ring tone sounds. 

Press the bell button until after 6 s a 
Prog2 sounds, keep the button 
pressed and after another 6 s a 
NoProg-tone sounds and ... 

…a ring tone sounds at the front 
door and indoor station.

1)

 

Release the bell 
button. 

Repeat the steps until you have programmed all bell buttons. 

4 End 

programming 

mode 

 

 

 

Shortly press the RUN/PROG button. 

The LED is on. 

The programming mode of the system is switched 
OFF.  

1)

 

If there sounds a Progsperr tone instead, at the front-door station a programming lock is set. You can deactivate the programming lock 
only with the Service Device TCSK or the configuration software configo

TM   

 
 
 
 

Содержание AVD Series

Страница 1: ...Product information Front door station series AVD AVE with integrated code lock...

Страница 2: ...nectingthelines 10 Connectthe floorpush button 10 Examplecircuit 11 Commissioningvideo 11 Extendedcodelock function 12 Initialoperation 12 Connectthe floorpush button 12 Settingthevolumeofmicrophonean...

Страница 3: ...lease in basic mode 21 Switching the lightinbasicmode 21 Repair 21 Exchanging the EEPROMstorage 21 FAQ 22 Errorindication detection 22 Cleaning 22 Conformity 22 Informationondisposal 23 Warranty 23 Se...

Страница 4: ...ilable for download at www tcsag de Usedsymbolsandwarningnotices Symbol signal word Explanation DANGER The signal word describes an endangering with a high level of risk Failure to observe this warnin...

Страница 5: ...communication lines e g J Y St Y with 0 8 mm diameter already existing lines modernisation with deviating cross sections can be used in compliance with the loop resistance requirementstoprotectagainst...

Страница 6: ...glass acknowledgement tone when pressing the bell button any bell bell button can be used to switch the light light symbol enclosed conversation time ex works 56 seconds can be adjusted with Service D...

Страница 7: ...onnectionterminal 13 connection forService Device bellbuttonextension 5 two colouredLED 14 nameplate illumination 6 Code lock keypad 15 volume controlmicrophone 7 bipolarpluggable screw terminal 16 vo...

Страница 8: ...o 0 button light switchinginbasic mode inputconfirmation in program ming mode button entryofcommandsequences andabortofincomplete com mand sequences in programming mode Technicaldata supply voltage 24...

Страница 9: ...vice damage The front door station must never be sealed using silicon Condensed water must be able to escape and evaporate Openingandclosingthehousing The lower aperture is connected to the aluminium...

Страница 10: ...losed in the delivery to connect lines Avoid damaging the device CAUTION Device damage The inner resistance of the door opener must not fall below 6 Ohm Strip the cable ends Connect the wires accordin...

Страница 11: ...ices of the system completely Then switch on the mains voltage Install the devices of the system completely Do not connect V1 and V2 with the P a or b wire Observe the polarity when connecting the vid...

Страница 12: ...is entered correctly and the contact according to the configuration of the switching input is effective Initial operation WARNING Danger to life due to electric shock Observe the safety regulations a...

Страница 13: ...oil Cut the name plates to the right size Push the name plate into the gab in the name plate glass from aside ill 11 Print the name plates on the special foil You can order the foil directly at TCS Wr...

Страница 14: ...dooropeneronlyduringanestablishedvoiceconnectionon off x setting the doorcallstandby time x setting the limitforthe conversation time x x setting thecalltime x setting the door release time x selectin...

Страница 15: ...he mains voltage The operating LED at the power supply and control unit is on Check if no programming lock is set Before you can reprogram an already programmed bell button you have to delete the prog...

Страница 16: ...programming mode Shortlypress theRUN PROGbutton The LED ison The programmingmodeofthesystem is switchedOFF 1 IftheresoundsaProgsperrtoneinstead atthefront doorstationaprogramminglockisset Youcandeact...

Страница 17: ...tone soundsand a ringtonesounds atthe front doorandindoorstation 1 Release thebell button 2b alternatively Programming via floor push button if the indoorstationis inaccessible Shortlypress the floor...

Страница 18: ...llbutton until the deletion tonesequence sounds Release thebellbutton 4 End programming mode Shortlypress theRUN PROGbutton The LED ison The programmingmodeofthesystem is switched OFF Programming the...

Страница 19: ...timesincorrectly Afterwards the codeinputislockedfor2min Thenstartagain Ifno command isenteredwithin the next2minutes the deviceauto matically quitsthe programming mode The LEDexpires Programming 2a...

Страница 20: ...ximumof8digits The programming lock cannot bedeactivatedmanually butonly withconfigoTM Determine the extended code lock function Input 12 function type Function type 0 externalcontacthas noinfluence 1...

Страница 21: ...ds the code inputis lockedfor2min Thenstartagain Switchingthelightinbasicmode 1 button to confirm button toconfirmwithoutenteringacode before Aspreconditionthefunctionmusthavebeenactivated programming...

Страница 22: ...xchange a andP wireorcorrect short circuit LEDexpires a wire isnotconnectedornot supplied Connectthe a wireorestablish power supply LEDexpires The buttonclamps press longer than 15sec release thebutto...

Страница 23: ...point Dispose the parts of the packaging in collecting tanks for cardboard and paper resp plastics Warranty We offer a simplified processing in case of warranty for qualified electricians Please conta...

Страница 24: ...wister Scholl Str 7 39307Genthin Germany FON 49 0 3933 8799 10 FAX 49 0 3933 879911 www tcsag de Subjecttotechnicalchanges TCS Hotline Germany FON 494194 9881188 Fax 494194 988129 Mail hotline tcsag d...

Отзывы: