- 77 -
4. PARAMETER SETTING
1
POWER
-
0
1
2
3
4
5
6
7
8
9
10
2
TRAVEL SPEED LIMIT
km/h
3
4
5
6
7
8
9
10
12
14
16
3
LIFT S
PEED
%
50
55
60
65
70
75
80
85
90
95
100
4
LIFT INCING LEV.
%
0
5
10
15
20
25
30
35
40
45
50
5
TILT S
PEED
%
0
10
20
30
40
50
60
70
80
90
6
ATT1 S
PEED
%
0
10
20
30
40
50
60
70
80
90
7
ATT2 S
PEED
%
0
10
20
30
40
50
60
70
80
90
8
SWITCH BACK REG.
%
0
10
20
30
40
50
60
70
80
90
9
ACCELERATOR OFF REG
%
0
10
20
30
40
50
60
70
80
90
10
BRAKE REG.
%
0
10
20
30
40
50
60
70
80
90
11
ANTI ROLL BACK
%
0
10
20
30
40
50
60
70
80
90
12
ACCELERATOR STAGE
-
0
1
2
3
4
5
6
7
8
9
10
13
SPEED ALARM OUTPUT S
PEED
km/h
3
4
5
6
7
8
9
10
12
14
16
14
STEERING SS
C LEVEL
km/h
3
4
5
6
7
8
9
10
12
14
16
15
16
SPEED LIMIT LEVEL
km/h
3
4
5
6
7
8
9
10
12
14
16
1
SEAT SW
2
SPEED
㩷㪣㪠㪤㪠㪫䇭㪪㪠
3
S MODE LIMIT
4
NEUTRAL SAFTY LOCK ACCEL.
-
5
NEUTRAL SAFTY LOCK PUMP LEV.
-
6
SPEED LIMIT
-
7
LIFT DOWN SWITCH
8
PUMP ACCELERATION MODE
-
9
SEAT SW DETECTION TIME
sec
0
1
1
2
2
3
3
4
4
4.5
5
10
SEAT SW OFF DELAY TIME
sec
0
2
4
6
8
10
15
20
30
60
㺙
11
SPEED LIMIT RATE BATT
%
0
10
20
30
40
50
60
70
80
90
12
PUMP UNIT LIMIT RATE
%
0
10
20
30
40
50
60
70
80
90
1
O
VER DISCHARGE LEVEL
-
1
2
3
4
5
6
7
8
9
10
2
A
UTO POWER OFF TIME
0
15
3
A
H
䇭
METER DISPLAY
R
ATE
4
H
EATER
5
S
PEED MODE LIMIT
6
P
ASS
WORD S
ET
7
B
ATTERY CAPACITY
935
8
C
ONTRAST
45
9
C
YLINDER
0
1
2
3
4
5
6
7
8
9
10
11
INT BUZZER TIME
1
2
3
4
5
6
7
8
9
10
PA
RA
ME
TE
R 3
1-44
46-90
OFF
O
N
OFF
O
N
1-14
16-90
TOTAL
DRIVE
PUMP
WORK
TRAVEL
OFF
O
N
No.
0
1
OFF
7
8
10
9
5
6
2
OFF
ON
OFF
ON
OFF
ON
H
N
Low
S
L
ON
ON
OFF
ON
OFF
ON
OFF
3
4
PA
RA
ME
TE
R 1
PA
RA
ME
TE
R 2
FB-8 Parameter Setting
T
able
Factory settings
Screen display
Item
Description
Unit
Remarks
T
ravel speed acceleration mode numbers
Max. speed in the “turtle” mode
Lift conduction ratio limit
Lift inching conduction ratio limit
T
ilt conduction ratio limit
A
TT1 conduction ratio limit
A
TT2 conduction ratio limit
Switchback regeneration intensity
Accelerator-of
f regeneration intensity
Brake OFF regeneration intensity
Anti-rollback regeneration intensity
Accelerator stage mode numbers
Speed at which alarm output is started with speed alarm output mode enabled
Lower speed limit when steering SSC is activated
The speed obtained when the max. speed limit flag is enabled.
Seat switch enabled
15 km/h or less
S mode disabled
Accelerator pedal neutral safety enabled
Load-handling neutral safety enabled
Max. speed limit enabled
Lift-down switch ON
Lift acceleration mode: High/N/Low/Super Low
The time required for seat switch OFF to be enabled.
The reset delay time after seat switch OFF is detected.
T
ruck speed limit rate that becomes ef
fective when the overdischarge alarm
signal is present.
Lift duty factor that is used when the overdischarge alarm signal is present.
Battery discharge indicator level at which overdischarge signal is issued.
The time required for auto power-of
f function to be enabled.
Items to be displayed on hour meter when key switch is turned on.
Not settable
Locked with the turtle switch pressed
Password mode ON/OFF
Battery capacity selection
Specify if an optional load meter is installed.
Number of beeps by buzzer
T
ravel speed acceleration level
T
ruck speed limit level
Lift speed level
Lift inching level
T
ilt speed level
A
TT1 speed level
A
TT2 speed level
Switchback regeneration level
Accelerator-of
f regeneration level
Brake OFF regeneration level
Anti-rollback regeneration level
Accelerator stage level
Speed alarm output level
Steering SSC level
Max. speed limit level
Flag setting (1)
Speed limit, vehicle inspection specifications
Flag setting (3)-1
Flag setting (3)-2
Flag setting (3)-3
Max. speed limit enabled
Flag setting (2)-1
Flag setting (2)-2
Seat switch detection time
Seat switch OFF delay time
T
ruck speed limit rate that becomes ef
fective
when the overdischarge alarm signal is present.
Load-handling operation limit rate during overdischarge
Overdischarge output level
Auto power-of
f time
Hour meter display switching over
Heater ON/OFF control
Fixed in the “turtle” mode
Password setting
Battery capacity
Contrast adjustment
Load meter constants
Number of beeps made by interlock buzzer
10: unlimited
0, 9, 10: OFF
, 1: VM 1t, 2: VM 2t,
3: VM 3t, 4: VM 3.5t, 5: VFHM 1t,
6: VFHM 2t, 7: VFHM 3t, 8: VFHM 3.5 t
Factory setting
Fixed to OFF
Settable in minutes. 0: OFF
The numbers correspond to the battery meter level.
Note displayed.
Always OFF
.
100
100
100
100
100
100
100
100
330
400
450
485
545
565
600
700
865
100
Содержание FB-8 Series
Страница 2: ......
Страница 4: ......
Страница 22: ......
Страница 26: ......
Страница 38: ...NOTE 1 BATTERY 12...
Страница 40: ...14 Fig 2 1 Drive Motor Installation DRIVE UNIT DRIVE AXLE DRIVE MOTOR 2 MOTORS...
Страница 92: ...NOTE 6 STEERING SYSTEM 66...
Страница 106: ...NOTE 6 STEERING SYSTEM 80...
Страница 126: ...100 Remove the oil seal from the front cover Fig 7 28 7 HYDRAULIC SYSTEM...
Страница 150: ...NOTE 8 LOAD HANDLING SYSTEM 124...
Страница 234: ...72 3 TROUBLESHOOTING GUIDE NOTE...
Страница 246: ...84 6 ELECTRIC WIRING NOTE...
Страница 258: ......
Страница 259: ...n m o m Z C F H d o H H M 0 M Z 0 m O m C O R P O R A T I O N T C M...