- 37 -
3. TROUBLESHOOTING GUIDE
< ERROR CODES SHOWN BY LED >
The error code numbers are displayed by an orange LED blinking on the controller CPU board.
Error codes are displayed as 2-digit numbers (decimal system). The 1’s digit and 10’s digit blink
at an interval of 0.5 seconds. The 100’s digit is not displayed for 3-digit error codes. The 1’s and 10’s
digits are separated by a 1-second OFF period. The 10’s digit is flashed first, and then the 1’s digit.
After flashing one error code, the LED will be OFF for 4 seconds before repeating the blinking
process.
If multiple errors occur, the last error code that was detected by the controller will be the one
displayed.
Because the error codes displayed on the LCD panel have a one-to-one correspondence with the
flashing LED error codes, the information described above is helpful if the LCD panel fails to display
the error codes.
(Example) Error code: 23 (Drive motor current sensor output abnormal)
■
Locations of LEDs
The same process
is repeated.
LED ON
LED OFF
LED blinks twice
Error code 23
LED blinks 3 times
For pump motor inverter
For drive motor
inverter
Содержание FB-8 Series
Страница 2: ......
Страница 4: ......
Страница 22: ......
Страница 26: ......
Страница 38: ...NOTE 1 BATTERY 12...
Страница 40: ...14 Fig 2 1 Drive Motor Installation DRIVE UNIT DRIVE AXLE DRIVE MOTOR 2 MOTORS...
Страница 92: ...NOTE 6 STEERING SYSTEM 66...
Страница 106: ...NOTE 6 STEERING SYSTEM 80...
Страница 126: ...100 Remove the oil seal from the front cover Fig 7 28 7 HYDRAULIC SYSTEM...
Страница 150: ...NOTE 8 LOAD HANDLING SYSTEM 124...
Страница 234: ...72 3 TROUBLESHOOTING GUIDE NOTE...
Страница 246: ...84 6 ELECTRIC WIRING NOTE...
Страница 258: ......
Страница 259: ...n m o m Z C F H d o H H M 0 M Z 0 m O m C O R P O R A T I O N T C M...