- 57 -
3. TROUBLESHOOTING GUIDE
(25)
-
22
: Load short circuit (Motor interphase short-
circuit)
Resets when the key switch is turned OFF.
-
91
: Overcurrent (Hardware OCL detected)
Resets when the key switch is turned OFF.
①
Check the drive motor cable terminals U, V, and W
for foreign matter.
Remove the foreign matter.
②
Check the drive motor cable for looseness.
Retighten.
③
Check the drive motor cable for short circuit.
Correct the cable.
④
Check the
CN1D-24
terminal on the drive motor
inverter unit for proper connection.
Connect properly.
⑤
Check the harness for the
CN1D-24
terminal on the
drive motor inverter unit.
Correct the wiring.
⑥
Refer to the repair procedure for Error Code 308.
⑦
Refer to the repair procedure for Error Code 216.
⑧
Replace the drive motor.
⑨
Replace the drive motor inverter unit.
(26)
-
82
: EEPROM SUM error
Resets when the key switch is turned OFF.
-
83
: EEPROM ACK error
Resets when the key switch is turned OFF.
①
Replace the drive motor inverter unit if this error
occurs frequently.
Содержание FB-8 Series
Страница 2: ......
Страница 4: ......
Страница 22: ......
Страница 26: ......
Страница 38: ...NOTE 1 BATTERY 12...
Страница 40: ...14 Fig 2 1 Drive Motor Installation DRIVE UNIT DRIVE AXLE DRIVE MOTOR 2 MOTORS...
Страница 92: ...NOTE 6 STEERING SYSTEM 66...
Страница 106: ...NOTE 6 STEERING SYSTEM 80...
Страница 126: ...100 Remove the oil seal from the front cover Fig 7 28 7 HYDRAULIC SYSTEM...
Страница 150: ...NOTE 8 LOAD HANDLING SYSTEM 124...
Страница 234: ...72 3 TROUBLESHOOTING GUIDE NOTE...
Страница 246: ...84 6 ELECTRIC WIRING NOTE...
Страница 258: ......
Страница 259: ...n m o m Z C F H d o H H M 0 M Z 0 m O m C O R P O R A T I O N T C M...