- 31 -
2. ELECTRICAL PARTS AND PROCEDURES FOR CHECKING
2.2.18 MOTOR THERMO-SENSOR
The drive and pump motors are provided with
thermo-sensors to check the motor temperature. If
the detection value of a thermo-sensor is judged to be
abnormal, the controller limits the electric current to
the corresponding motor.
Checking procedure
①
Disconnect the motor sensor connectors.
②
Set the multimeter to a resistance range of
x1000 Ω. Measure the resistance between the
terminals according to the table given below.
③
Determine whether the sensor is defective or not
according to the measured resistance.
Normal value (rough guide)
10°C [50°F]: about 20 kΩ
20°C [68°F]: about 13 kΩ
30°C [86°F]: about 9 kΩ
50°C [122°F]: about 4.4 kΩ
Voltage checking
Measurement terminals (wire color)
Normal value
Drive motor
Pump motor
+
–
+
–
CN11-4
(WG)
CN11-3
(WR)
CN1-22
(LW)
N terminal
0.2 to 4.8 V