17
Additional battery loads are
consuming too much current
during charging
Turn-off or disconnect all
battery loads
Charge current is too low.
High ambient temperature
Try to lower the ambient
temperature around the
charger
Charger is operating in the
absorption charging stage.
Do nothing. The battery is
almost fully charged and
consumes less current by
itself.
Charge voltage is too low.
The charge voltage is being
compensated by the battery
temperature sensor to
protect the battery.
Do nothing or try to cool
down the ambient
temperature around the
battery.
Wrong battery type selected,
or charge voltage needs to
be adjusted
Select the correct battery
type or adjust the charge
voltage in the setup menu
DC cables too thin
Install larger DC cables. See
the DC cable size table in
chapter 2.3.
Battery load current is higher
than the charger’s output
current.
Reduce or remove the
battery load.
LEDs blink red
Error detected
Check LED error table in
chapter 3.4
If none of the above remedies will help solving the problem you encounter, it
’
s best to
contact your local TBS distributor for further help and/or possible repair of your Omnicharge
DC unit. Do not disassemble the charger yourselves as this will void your warranty.